70
CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | CI/FCB400/FCH400-EN REV. H
... 6 Electrical connections
... Digital communication
Ethernet card status LEDs
The 6 LEDs on the Ethernet card indicate the status of each port and the network.
To enable card status indication in the upper HMI Line, navigate to 'Display / Display Tag / Ethernet Status'.
A Port 1
B Activity 1
C Port 2
Figure 62: Ethernet card status LEDs
LED
A Port 1
B Activity 1
C Port 2
D Activity 2
E Module Status (Mod)
F Network Status (Net)
Status
ON
OFF
Flashing or ON
OFF
ON
OFF
Flashing or ON
OFF
green, ON
green, Flashing (1 Hz)
green/ red, Flashing (1Hz)
red, Flashing (1 Hz)
red, ON
OFF
green, ON
green, Flashing (1 Hz)
green/ red, Flashing (1Hz)
red, ON
OFF
red, flashing (1 Hz)
D Activity 2
E Module Status (Mod)
F Network Status (Net)
HMI display
Mod showing <G> continously
Mod changing between <G> and < >
Mod changing between <R> and < >
Mod showing <R> continously
Mod showing < > continously
Net showing <G> continously
Net changing between <G> and < >
Net showing <R> continously Dublicated IP address. Device has detected
Net showing < > continously
Mod changing between <R> and < >
Description
Network connection (link up)
No network
Network connection (link up)
No network
Device ready for Operation.
Working properly
Standby. Device not configured yet
Device performs "Power-On" Test
Simple Error, which can be fixed
Major Error.
Non removable serious error
No Power
Connected. Device has at least one
established connection
No Connection.
Device did not establish any connections,
but was assigned an IP address
Device performs "Power-On" Test
that the device IP address is already in use
No supply voltage or IP Address.
Connection timeout
Traffic
No traffic
Traffic
No traffic