CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | CI/FCB400/FCH400-EN REV. H
Wiring with different network topologies
A Daisy-chain
B Ring
Figure 57: Connection topologies
Ethernet Option Cards are designed only for use in hazardous applications Zone 2 / Division 2 or general purpose areas.
The output circuits are designed so that different topologies such as daisy chain or point to point can be connected.
See Installation diagram for detailed information.
•
It is not permitted to combine both topologies.
•
Ethernet communication is only available for installations in Zone 2/Division 2 or general purpose
•
The rated voltage of these non-intrinsically safe circuits are UM = 57 V.
Topology
Star
C Star
No. Ethernet cables
No. wires in
connected
Ethernet cable
1
1
1
1
PoE
Port
Clamp
Function
4
No
1
1
1
3
4
8
No
1
1
2
3
4
2
1
2
3
4
4
Yes
1
1
2
3
4
8
Yes
1
1
2
3
4
2
1
2
3
4
65
Cable
RD+
white / orange
RD−
orange
TD+
white / green
TD−
green
RD+
white / orange
RD−
orange
TD+
white / green
TD−
green
Spare 1+
white / blue
Spare 1−
blue
Spare 2+
white / brown
Spare 2−
brown
Recommendation:
Use cable with 8 wires
RD+
white / orange
RD−
orange
TD+
white / green
TD−
green
Spare 1+
white / blue
Spare 1−
blue
Spare 2+
white / brown
Spare 2−
brown