Table 2-5.5: MHC-V26W/D2RN8 heating capacity - peak values
Outdoor
air temp.
30
⁰C DB
HC
PI
COP
-25.0
8466 6031 1.40 7648 6378 1.20
-20.0
12858 6120 2.10 11617 6472 1.79 10376 6824 1.52
-15.0
19196 7250 2.65 19196 8261 2.32 16826 9394 1.79 14361 10561 1.36 13648 11345 1.20
-7.0
23890 8383 2.85 24743 9597 2.58 24316 10102 2.41 24743 10962 2.26 24743 11645 2.12 16704 12198 1.37 12590 10175 1.24
-2.0
29211 8974 3.26 28195 9523 2.96 27665 10252 2.70 27099 11000 2.46 26142 11863 2.20 23013 12689 1.81 21303 14295 1.49
2.0
32747 8757 3.74 31640 10400 3.04 31078 10890 2.85 30476 12086 2.52 30411 12867 2.36 27207 12236 2.22 25583 12690 2.02
7.0
29927 7459 4.01 29083 8074 3.60 28240 8690 3.25 27396 9305 2.94 27120 10382 2.61 26843 11459 2.34 24306 11469 2.12
15.0
32415 7394 4.38 30789 7789 3.95 30707 8536 3.60 30624 9283 3.30 28930 9180 3.15 26556 8851 3.00 24905 8751 2.85
20.0
32835 7086 4.63 32475 7723 4.21 30468 7931 3.84 30126 8535 3.53 28453 8482 3.35 26780 8428 3.18 25107 8375 3.00
25.0
33747 6931 4.87 33140 7449 4.45 32533 7966 4.08 31926 8484 3.76 30146 8472 3.56 28366 8460 3.35 26586 8448 3.15
30.0
35360 6947 5.09 34511 7366 4.69 33662 7785 4.32 33725 8432 4.00 31839 8462 3.76 29952 8491 3.53 28066 8521 3.29
35.0
12722 1759 7.23 12431 1947 6.38 12140 2136 5.68 11849 2324 5.10 11557 2642 4.37 11264 2959 3.81
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Peak heating capacity values do not take account of capacity drops caused by frost accumulation and during defrosting.
Table 2-5.6: MHC-V26W/D2RN8 heating capacity - integrated values
Outdoor
air temp.
30
⁰C DB
HC
PI
COP
-25.0
7307 5685 1.29 6906 6162 1.12
-20.0
11099 5769 1.92 10490 6253 1.68 9881 6737 1.47
-15.0
18848 7395 2.55 17133 7723 2.22 14326 8879 1.61 11409 10070 1.13 11262 10758 1.05
-7.0
23620 8628 2.74 23460 9316 2.52 22069 9642 2.29 21453 10307 2.08 20450 10803 1.89 15277 11629 1.31 11515 9701 1.19
-2.0
24677 8515 2.90 24199 8875 2.73 24145 9742 2.48 24074 10634 2.26 22101 11100 1.99 18394 10781 1.71 15966 10988 1.45
2.0
25523 7910 3.23 25438 8780 2.90 25806 9822 2.63 26170 10896 2.40 25967 11612 2.24 23098 11052 2.09 21594 11019 1.96
7.0
29927 7459 4.01 29083 8074 3.60 28240 8690 3.25 27396 9305 2.94 27120 10382 2.61 26843 11459 2.34 24306 11469 2.12
15.0
32415 7394 4.38 30789 7789 3.95 30707 8536 3.60 30624 9283 3.30 28930 9180 3.15 26556 8851 3.00 24905 8751 2.85
20.0
32835 7086 4.63 32475 7723 4.21 30468 7931 3.84 30126 8535 3.53 28453 8482 3.35 26780 8428 3.18 25107 8375 3.00
25.0
33747 6931 4.87 33140 7449 4.45 32533 7966 4.08 31926 8484 3.76 30146 8472 3.56 28366 8460 3.35 26586 8448 3.15
30.0
35360 6947 5.09 34511 7366 4.69 33662 7785 4.32 33725 8432 4.00 31839 8462 3.76 29952 8491 3.53 28066 8521 3.29
35.0
12722 1759 7.23 12431 1947 6.38 12140 2136 5.68 11849 2324 5.10 11557 2642 4.37 11264 2959 3.81
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Integrated heating capacity values take account of capacity drops caused by frost accumulation and during defrosting.
24
35
40
HC
PI
COP
HC
PI
35
40
HC
PI
COP
HC
PI
Midea CAC Confidential
1
LWT (⁰C)
45
COP
HC
PI
COP
HC
1
LWT (⁰C)
45
COP
HC
PI
COP
HC
50
55
PI
COP
HC
PI
COP
50
55
PI
COP
HC
PI
COP
60
HC
PI
COP
60
HC
PI
COP
202005

Advertisement

Table of Contents
loading

Table of Contents