Midea M thermal Mono Series Engineering Data page 26

Hide thumbs Also See for M thermal Mono Series:
Table of Contents

Advertisement

Table 2-5.7: MHC-V30W/D2RN8 heating capacity - peak values
Outdoor
air temp.
30
⁰C DB
HC
PI
COP
-25.0
7869 6255 1.26 7181 6605 1.09
-20.0
13266 6606 2.01 12076 6976 1.73 10887 7347 1.48
-15.0
19411 7517 2.58 19955 8898 2.24 16890 10236 1.65 13704 11616 1.18 13400 12465 1.08
-7.0
24516 8730 2.81 24888 9928 2.51 25711 10959 2.35 26547 12019 2.21 26933 12887 2.09 22278 14100 1.58 16470 12795 1.29
-2.0
30739 9892 3.11 29428 10381 2.83 28618 11064 2.59 27762 11765 2.36 27612 12944 2.13 27907 14716 1.90 27664 17438 1.59
2.0
33318 8907 3.74 31942 9481 3.37 31111 11374 2.74 30700 12748 2.41 30582 13511 2.26 29866 13781 2.17 28047 13980 2.01
7.0
31177 8100 3.85 31754 9509 3.34 30825 9810 3.14 30992 11268 2.75 31077 12097 2.57 30563 13819 2.21 27332 12943 2.11
15.0
31835 7396 4.30 32695 8637 3.79 34334 10108 3.40 36014 11636 3.09 34020 11332 3.00 32585 11237 2.90 27197 9762 2.79
20.0
32636 7055 4.63 32977 8075 4.08 34150 9322 3.66 35340 10620 3.33 33608 10510 3.20 32477 10618 3.06 27137 9328 2.91
25.0
33876 6869 4.93 33763 7710 4.38 34535 8776 3.94 35302 9885 3.57 33766 9942 3.40 32877 10226 3.22 27519 9093 3.03
30.0
36747 7036 5.22 36198 7749 4.67 36587 8684 4.21 36947 9657 3.83 35488 9862 3.60 34721 10306 3.37 29225 9313 3.14
35.0
12696 1782 7.12 12405 1972 6.29 12113 2161 5.61 11821 2351 5.03 11577 2665 4.34 11333 2979 3.80
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Integrated heating capacity values take account of capacity drops caused by frost accumulation and during defrosting.
Table 2-5.8: MHC-V30W/D2RN8 heating capacity - integrated values
Outdoor
air temp.
30
⁰C DB
HC
PI
COP
-25.0
7406 6210 1.19 7093 6800 1.04
-20.0
11249 6302 1.79 10773 6901 1.56 10288 7500 1.37
-15.0
19103 8078 2.36 17595 8523 2.06 14915 9884 1.51 12050 11295 1.07 11845 11459 1.03
-7.0
23940 9425 2.54 23261 9927 2.34 22977 10735 2.14 22659 11561 1.96 21508 11943 1.80 16540 13786 1.20 12228 11043 1.11
-2.0
25011 9301 2.69 24851 9795 2.54 25138 10846 2.32 25427 11928 2.13 23246 12272 1.89 19934 12793 1.56 17952 12818 1.40
2.0
24994 8075 3.10 26021 9085 2.86 25959 10220 2.54 28191 12317 2.29 26388 11998 2.20 24651 12493 1.97 23085 11821 1.95
7.0
31177 8100 3.85 31754 9509 3.34 30825 9810 3.14 30992 11268 2.75 31077 12097 2.57 30563 13819 2.21 27332 12943 2.11
15.0
31835 7396 4.30 32695 8637 3.79 34334 10108 3.40 36014 11636 3.09 34020 11332 3.00 32585 11237 2.90 27197 9762 2.79
20.0
32636 7055 4.63 32977 8075 4.08 34150 9322 3.66 35340 10620 3.33 33608 10510 3.20 32477 10618 3.06 27137 9328 2.91
25.0
33876 6869 4.93 33763 7710 4.38 34535 8776 3.94 35302 9885 3.57 33766 9942 3.40 32877 10226 3.22 27519 9093 3.03
30.0
36747 7036 5.22 36198 7749 4.67 36587 8684 4.21 36947 9657 3.83 35488 9862 3.60 34721 10306 3.37 29225 9313 3.14
35.0
12696 1782 7.12 12405 1972 6.29 12113 2161 5.61 11821 2351 5.03 11577 2665 4.34 11333 2979 3.80
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Integrated heating capacity values take account of capacity drops caused by frost accumulation and during defrosting.
202005
35
40
HC
PI
COP
HC
PI
35
40
HC
PI
COP
HC
PI
Midea CAC Confidential
1
LWT (⁰C)
45
COP
HC
PI
COP
HC
1
LWT (⁰C)
45
COP
HC
PI
COP
HC
M thermal Mono
50
55
PI
COP
HC
PI
COP
50
55
PI
COP
HC
PI
COP
60
HC
PI
COP
60
HC
PI
COP
25