M thermal Mono
5.6 AHS provides heat for DHW
Figure 1-5.6: AHS provides heat for DHW
Table 1-5.6: AHS provides heat for DHW
Legend
1
Outdoor unit
1.1
Manometer
1.2
Pressure relief valve
1.3
Expansion vessel
1.4
Plate heat exchanger
1.5
Air purge valve
1.6
Flow switch
1.7
P_i: Circulation pump inside the unit
2
Y-shape filter
3
Stop valve (field supplied)
4
Wired controller
5
Stop valve (field supplied)
6
Drain valve (field supplied)
7
Fill valve (field supplied)
8
Balance tank (field supplied)
8.1
Air purge valve
Notes:
1.
The example is just for application illustration; please confirm the exact installation method according to the installation manual.
14
8.2
9
10
11
12
12.1
12.2
12.3
13
14
15
16
17
18
FHL 1...n
Midea CAC Confidential
Drain valve
Expansion vessel (field supplied)
P_o: Outside circulation pump (field supplied)
Collector / Distributor (field supplied)
Domestic hot water tank (field supplied)
Air purge valve
Heat exchanger coil
Booster heater
T5: Temperature sensor
Hot water tap(field supplied)
P_d: Cycle hot water pump(field supplied)
One way valve(field supplied)
Additional heat source(field supplied)
SV1: 3-way valve (field supplied)
Floor heating loop (field supplied)