5.1 Heating Capacity Tables (Test standard:EN14511)
Table 2-5.1: MHC-V18W/D2RN8 heating capacity - peak values
Outdoor
air temp.
30
⁰C DB
HC
PI
COP
-25.0
10191 6401 1.59 9069 6788 1.34
-20.0
12939 6013 2.15 11515 6376 1.81 10091 6739 1.50
-15.0
20078 7699 2.61 19027 8151 2.33 17841 9048 1.97 15171 9112 1.66 12715 9070 1.40
-7.0
24296 8831 2.75 23577 9241 2.55 23266 9824 2.37 20360 9253 2.20 18743 9163 2.05 10735 8784 1.22 8565 7170 1.19
-2.0
26720 7980 3.35 25246 8346 3.02 24294 8836 2.75 23360 9301 2.51 21178 9626 2.20 13926 9310 1.50 11838 8353 1.42
2.0
25962 6948 3.74 25494 7477 3.41 25026 8006 3.13 24558 8535 2.88 23848 9184 2.60 20623 8764 2.35 19015 9387 2.03
7.0
21884 5019 4.36 20738 5313 3.90 19593 5608 3.49 18447 5902 3.13 18424 6805 2.71 18401 7707 2.39 18378 8610 2.13
15.0
23370 5157 4.53 22078 5109 4.32 20786 5061 4.11 20886 5372 3.89 19338 5484 3.53 19182 5954 3.22 19026 6424 2.96
20.0
25031 5384 4.65 23779 5329 4.46 22527 5273 4.27 21275 5217 4.08 20829 5569 3.74 20382 5921 3.44 19935 6273 3.18
25.0
24785 5211 4.76 23660 5152 4.59 22535 5093 4.43 21410 5033 4.25 20725 5250 3.95 20040 5468 3.67 19355 5685 3.40
30.0
26328 5423 4.85 25240 5356 4.71 24153 5289 4.57 23065 5222 4.42 22110 5330 4.15 21154 5437 3.89 20199 5545 3.64
35.0
12774 1712 7.46 12484 1898 6.58 12195 2085 5.85 11905 2271 5.24 11516 2596 4.44 11127 2920 3.81
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Peak heating capacity values do not take account of capacity drops caused by frost accumulation and during defrosting.
Table 2-5.2: MHC-V18W/D2RN8 heating capacity - integrated values
Outdoor
air temp.
30
⁰C DB
HC
PI
COP
-25.0
8684 6028 1.44 7841 6518 1.20
-20.0
11025 5663 1.95 9955 6123 1.63 8885 6583 1.35
-15.0
15468 6961 2.22 14693 6973 2.11 14167 8250 1.72 12439 8742 1.42 10822 9073 1.19
-7.0
21075 8180 2.58 19906 8414 2.37 19071 8803 2.17 16156 8169 1.98 14349 7978 1.80 10075 8515 1.18 8038 7435 1.08
-2.0
22479 7183 3.13 20516 7346 2.79 19021 7627 2.49 17570 7892 2.23 16322 8364 1.95 12613 8870 1.42 10722 8815 1.22
2.0
20355 5816 3.50 20228 6397 3.16 20101 6979 2.88 19974 7560 2.64 19936 8410 2.37 17735 8254 2.15 16838 8572 1.96
7.0
21884 5019 4.36 20738 5313 3.90 19593 5608 3.49 18447 5902 3.13 18424 6805 2.71 18401 7707 2.39 18378 8610 2.13
15.0
23370 5157 4.53 22078 5109 4.32 20786 5061 4.11 20886 5372 3.89 19338 5484 3.53 19182 5954 3.22 19026 6424 2.96
20.0
25031 5384 4.65 23779 5329 4.46 22527 5273 4.27 21275 5217 4.08 20829 5569 3.74 20382 5921 3.44 19935 6273 3.18
25.0
24785 5211 4.76 23660 5152 4.59 22535 5093 4.43 21410 5033 4.25 20725 5250 3.95 20040 5468 3.67 19355 5685 3.40
30.0
26328 5423 4.85 25240 5356 4.71 24153 5289 4.57 23065 5222 4.42 22110 5330 4.15 21154 5437 3.89 20199 5545 3.64
35.0
12774 1712 7.46 12484 1898 6.58 12195 2085 5.85 11905 2271 5.24 11516 2596 4.44 11127 2920 3.81
Abbreviations:
LWT: Leaving water temperature (°C )
HC: Total heating capacity (W)
PI: Power input (W)
Notes:
1.Integrated heating capacity values take account of capacity drops caused by frost accumulation and during defrosting.
22
35
40
HC
PI
COP
HC
PI
35
40
HC
PI
COP
HC
PI
Midea CAC Confidential
1
LWT (⁰C)
45
COP
HC
PI
COP
HC
1
LWT (⁰C)
45
COP
HC
PI
COP
HC
50
55
PI
COP
HC
PI
COP
50
55
PI
COP
HC
PI
COP
60
HC
PI
COP
60
HC
PI
COP