Advertisement

5. Data Report

The device will immediately send a version packet report and the data of attribute report.
The device sends data according to the default configuration before any other configuring.
Default Setting:
MaxTime: Max Interval = 15 min = 900s
MinTime: Max Interval = 15 min = 900s (By default, the current voltage is detected every Min Interval.)
BatteryVoltageChange = 0x01 (0.1v)
ADC Raw Value Change = 0x64 (100 mV)
Current Change ---- 0x02 (2 mA)
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
3. If there are special customized shipments, the setting will be changed according to customer's requirements.)
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit: second)
Any number between
1~65535
// configuration need to greater than 0x50 (80 mV)
to resolve uplink data.
Max Interval
(Unit: second)
Any number between
1~65535
Reportable Change
Reportable Change
Can not be 0
5
Current Change<
Current Change≥
Reportable Change
Report
per Min Interval
per Max Interval
Report