netvox R718F User Manual

netvox R718F User Manual

Wireless reed switch open / close detection sensor

Advertisement

Quick Links

Model:R718F
Wireless Reed Switch Open/Close Detection Sensor
Wireless Reed Switch Open/Close Detection
Sensor
R718F
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict
confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The
specifications are subject to change without prior notice.

Advertisement

Table of Contents
loading

Summary of Contents for netvox R718F

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ..................................2 2. Appearance ..................................2 3. Main Features ................................... 3 4. Set up Instruction ................................3 5. Data Report ..................................5 6. Installation ..................................8 7. Information about Battery Passivation ........................... 10 7.1 To determine whether a battery requires activation ....................10 7.2 How to activate the battery .............................
  • Page 3: Introduction

    1. Introduction R718F is a wireless long-distance reed switch detection device which is Class A devices based on the LoRaWAN protocol of Netvox and is compatible with the LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance.
  • Page 4: Main Features

     Low power consumption and long battery life Note*: Battery life is determined by the sensor reporting frequency and other variables, please refer to http://www.netvox.com.tw/electric/electric_calc.html On this website, users can find battery life of various models in different configurations. 4.Set up Instruction...
  • Page 5 Network Joining Turn on the device to search the network. Never joined the network The green indicator stays on for 5 seconds: success The green indicator remains off: fail Turn on the device to search the previous network. Had joined the network The green indicator stays on for 5 seconds: success (Not restore to the factory setting) The green indicator remains off: fail...
  • Page 6: Data Report

    The cycle of the device sending the data report is according to the default. The interval between two reports must be the Mintime. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index to resolve uplink data.
  • Page 7 BatteryChange Reserved 0x01 (2bytes Unit: s) (2bytes Unit: s) (1byte Unit: 0.1v) (4Bytes, Fixed 0x00) ConfigReport Status Reserved 0x81 (0x00_success) (8Bytes, Fixed 0x00) R718F 0x1D ReadConfig Reserved 0x02 (9Bytes, Fixed 0x00) ReportReq ReadConfig MinTime MaxTime BatteryChange Reserved 0x82 (2bytes Unit: s) (2bytes Unit: s) (1byte Unit: 0.1v)
  • Page 8 Example for MinTime/MaxTime logic: Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime Sleeping(MinTime) Sleeping(MinTime) Wake up and collects data Wakes up and collects data Wakes up and collects data REPORTS 3.6V REPORTS 3.6V REPORTS 3.6V Note: MaxTime=MinTime.
  • Page 9: Installation

    6. Installation 2. When the door or window is opened, the reed switch 1. R718F has a built-in magnet (as the figure below). When probe is separated from the magnet, and the device sends installed, it can be attached to the surface of an object with an alarm message about the opening.
  • Page 10 When installing the device, the magnet must move along the X axis relative to the sensor. If the magnet moves along the Y axis relative to the sensor, it will cause repeated reports due to the magnetic field. Note: Please do not disassemble the device unless it is required to replace the batteries. Do not touch the waterproof gasket, LED indicator light, function keys when replacing the batteries.
  • Page 11: Information About Battery Passivation

    7. Information about Battery Passivation Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density. However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high.
  • Page 12: Important Maintenance Instruction

    8. Important Maintenance Instruction The device is a product with superior design and craftsmanship and should be used with care. The following suggestions will help you use the warranty service effectively. • Keep the equipment dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits.

Table of Contents