3.4. Connector Information
3.4.1. Ethernet Connection TX
Illustration
Table 3. Ethernet connection TX
3.4.2. Power Input
Illustration
Position
1
1
2
2
3
4
3
4
Table 4. Power input
Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the
negative input for both supplies are -COM. Connect the primary voltage (e.g. +24 VDC) to
the +DC1 pin and return to one of the -COM pins on the power input.
3.4.3. I/O Connection
Illustration
1
2
3
4
Table 5. I/O connection
Pin no.
Signal
1
TD+
2
TD-
3
RD+
4
-
5
-
6
RD-
7
-
8
-
Shield
Product
Direction
marking
+DC1
Input
+DC2
Input
-COM
Input
-COM
Input
Pin no.
Product marking
1
Status +
2
Status -
3
Digital in +
4
Digital in -
Lynx L105-S1 and L205-S1
Direction
Description
In/Out
Transmitted/Received data
In/Out
Transmitted/Received data
In/Out
Transmitted/Received data
-
Not connected
-
Not connected
In/Out
Transmitted/Received data
-
Not connected
-
Not connected
Connected to PE
Description
Supply
voltage
Supply
voltage
Common
Common
Direction
Output
Output
Input
Input
Description
Alarm relay (status) contact
Alarm relay (status) contact
Digital in +
Digital in -
11