The device variable refers to the physical slot num-
ber on the PCI bus. The device number is in hex; you
must convert it to a decimal number. The device
number for the built-in AIC-7880 host adapter is 10;
the device number for the built-in AIC-7860 control-
ler is 11.
Table 3-1 shows the PCI bus number and device
numbers for the five PCI expansion slots in the
PowerEdge 4100 system:
Table 3-2. Expansion Slot Bus Numbers and
Device Numbers
Expansion Slot
Number
4
5
6
7
8
NOTE: The device slot number identified through
SCSISelect is not the same as the slot number needed
to load the driver through the load command line.
Use the following formula to calculate the slot
number:
slot number = (bus * 100) + device + 16
For example, if the bus:device number is 0:06h (that
is, bus 0, device 6), then the slot number is 22 (22 =
[0 * 100] + 6 + 16). The slot number for the built-in
AIC-7880 host adapter is 126 (126 = [1 * 100] + 10
+ 16).

Installing NetWare and the Driver

This subsection describes how to install the aic7870.dsk
driver at the same time you install NetWare 3.12 or 4.x. If
NetWare 3.12 or 4.x is already installed and you wish to
install or update the aic7870.dsk driver, see "Using Net-
Ware to Install or Update the Driver" found later in this
section.
3-12
Dell PowerEdge 4100/180 and 4100/200 Systems User's Guide
PCI Bus
Device
Number
Number
1
13
1
8
0
19
0
17
0
16

Performing a NetWare 4.x Installation

Follow these steps only if you are installing or upgrading
NetWare 4.x for the first time:
1.
Make backup copies of all Novell diskettes, and
use those backup copies as your working
diskettes.
2.
Boot MS-DOS on your computer.
3.
Change to the directory where the installation
files are found. For a CD-ROM, the subdirectory
is similar to d:\netware4.0\english\.
4.
Type install and press <
5.
Select
INSTALL NEW NETWARE V4.x
installing NetWare 4.x for the first time, or
UPGRADE NETWARE V3.1x OR V4.x
upgrading to NetWare 4.x.
6.
Follow the instructions in the NetWare User's
Guide for partitioning, creating a server name,
and checking the internetwork packet exchange
(IPX) network number.
7.
When a screen appears asking you to select a disk
driver, press <
INSERT
8.
Insert the NetWare 4.x driver diskette that you
created earlier into the diskette drive.
If you have not already created this diskette, refer to
Chapter 2, "Using the Dell Server Assistant CD," for
instructions.
9.
Press <
>, and specify the path to the aic7870.dsk
F3
driver for NetWare (for example, a:\scsi).
10. Select the aic7870.dsk driver and press <
NOTE: Specific help text for each driver appears in
the middle of the screen as you scroll down the list.
The Loaded Drivers window below the list of avail-
able drivers displays the names of drivers that are
loaded and operational. For a new installation, this
list is initially empty. For a selective installation, the
list shows the diskette drivers already running.
11. Specify the server directory (usually, c:\nwserver)
and press <
>. The installation program
ENTER
copies the necessary files to this directory.
>.
ENTER
if you are
if you are
>.
ENTER
>.