Preparation

Pressure Relief Procedure

To reduce risk of injury, follow this procedure whenever
you see this symbol throughout this manual, Also, per-
form this procedure whenever you:
• Stop spraying
• Check or repair any part of this system
• Install or clean spray nozzle
1. Turn power switch (K) OFF.
ti9165a
2. Trigger gun into material hopper.
3. Open gun air valve.
ti8528a

Grounding and Electrical Requirements

This sprayer must be grounded. Grounding reduces the
risk of electrical shock by providing an escape wire for
the electrical current. The sprayer cord includes a
grounding wire with an appropriate grounding plug. The
plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
3A1174B
ti8371a
Check with a qualified electrician or serviceman if
grounding instructions are not completely understood,
or if in doubt as to whether the product is properly
grounded. Do not modify plug provided; if it will not fit
the outlet, have proper outlet installed by a qualified
electrician.
120V AC Systems
This equipment requires a 120V AC, 60 Hz, 15A cir-
cuit with a grounding receptacle. Do not use an
adapter with this product.
Extension Cords
Use only an extension cord with an undamaged,
3-prong plug.
For 25 to 50 ft (7.6 to 15.2 m) cords, use 3-wire, 14
2
AWG (1.5 mm
) minimum.
For up to 100 ft. (30.48 m) cord, use 3-wire, 12 AWG
2
(2.5 mm
) minimum.

Additional Required Equipment

Auxiliary Air Compressor
Minimum Requirements: 3.5 CFM @ 40 psi or 2.5 CFM
@ 90 psi (maximum 100 psi)
3/8 x 25 ft minimum airline rated @ 120 psi/min
Alternate Power - Generator Requirements
3500 W (3.5 kW) minimum
Preparation
ti2810a
7