Operation; Trigger Lock; Pressure Relief Procedure - AIRLESSCO SP200 A Series Operation

Electric airless sprayer
Table of Contents

Advertisement

Operation

Trigger Lock

Always engage the trigger lock when you stop spraying
to prevent the gun from being triggered accidentally by
hand or if dropped or bumped.
ti8908a
Trigger Locked

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever
you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
1. Engage trigger lock.
2. Turn power switch OFF and unplug power cord.
Pressure Control Knob Settings
High Pressure
Spray
NOTE: To select function, align symbol on pressure control knob with setting indicator on sprayer.
333089A
ti8909a
Trigger Unlocked
ti2018a
Low Pressure
Prime/
Spray
3. Turn Prime/Spray valve to PRIME position.
4. Disengage trigger lock. Hold gun firmly to side of
pail. Trigger the gun to relieve pressure.
5. Engage trigger lock.
NOTE: Leave Prime/Spray valve in the PRIME position
until you are ready to spray again.
6. If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved after follow-
ing the steps above, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve
pressure gradually, then loosen completely. Clear
hose or tip obstruction. Read Unclogging Spray Tip,
page 16.