Setup; Pressure Relief Procedure - AIRLESSCO 25M223 Operation - Repair - Parts

Striping gun
Table of Contents

Advertisement

Setup

Pressure Relief Procedure

Follow the Pressure Relief
Procedure whenever you see this
symbol.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection or splashed
fluid, follow the Pressure Relief
Procedure whenever sprayer is stopped
and before sprayer is cleaned or checked,
and before equipment is serviced.
1.
Turn sprayer OFF.
2.
Engage the trigger lock. Always engage
the trigger lock when sprayer is stopped
to prevent the gun from being triggered
accidentally.
3.
Turn pressure control knob to lowest
setting.
3A4408B
4.
Put drain tube into a waste pail and turn
Prime/Spray valve in PRIME position
(drain) to relieve pressure.
5.
Hold the gun firmly to a pail. Point gun
into pail. Disengage the trigger lock and
trigger the gun to relieve pressure.
ti30177a
6.
Engage the trigger lock.
7.
If you suspect the spray tip or hose is
clogged or that pressure has not been
fully relieved:
a.
b.
ti30174a
c.
ti30175a
VERY SLOWLY loosen the tip
guard retaining nut or the hose end
coupling to relieve pressure
gradually.
Loosen the nut or coupling
completely.
Clear the obstruction in the hose or
tip.
Setup
ti30176a