Safety instructions
2.3 Safety during electrical installation
Damage to sockets and charging cable
Inspect sockets and the charging cable for damage on a regular basis. Damaged charging
cables endanger safe operation.
If you detect damage to the charging cable, do not commission the cable or stop a running
charging process. Disconnect the charging cable from the mains without touching it. Ensure
that the device cannot be switched back on.
If you notice damage to the charging station, take it out of service. To do this, disconnect the
charging station from power supply and secure it against a restart.
Defective connectors or cables may cause fire. The qualified personnel must decommission
the system and replace the damaged components immediately.
Condensed water
Before commissioning the charging station, a skilled electrician must check whether there is
condensed water in the charging station. Remove even small amounts of condensed water
before commissioning.
Moisture in the charging station can lead to electric shock.
Do not switch off the power supply for an extended period of time after commissioning. This
will prevent condensation in the charging station. If the charging station is to be switched off
for a longer period of time, you need to provide suitable moisture protection.