Troubleshooting And Maintenance; Vantage Pro2 Troubleshooting Guide - DAVIS Vantage Pro2 Console Manual

Davis vantage pro2 weather-accessories: user guide
Hide thumbs Also See for Vantage Pro2:
Table of Contents

Advertisement

Chapter 4

Troubleshooting and Maintenance

Vantage Pro2 Troubleshooting Guide

While your Vantage Pro2 weather station is designed to provide years of trou-
ble-free operation, occasional problems may arise. If you are having a prob-
lem with your station, please consult this troubleshooting guide before calling
Davis technical support. You may be able to quickly solve the problem your-
self. If you need help, please see "One Year Limited Warranty" on page 40.
Note:
Refer to the ISS Installation Manual for additional troubleshooting information.
Problem
Display is blank
Display shows dashes in
place of weather data
Console is sluggish or does
not work at low temperatures
Display "locks up"
Inside humidity seems too
high or too low
Wind speed reading seems
too high or too low.
Wind speed reads 0 either all
the time or intermittently
Dew Point reading seems
too high or too low
T
4-1: T
ABLE
ROUBLESHOOTING
Unit is not receiving power. Check the power adapter connections
and/or replace batteries.
ISS not plugged in (cabled station). See ISS manual.
Sensors not transmitting (wireless station). See ISS (or other
transmitter) manual.
Console not receiving (wireless station) - See "Troubleshooting
Reception Problems" on page 35.
A reading has exceeded the limits indicated in the specifica-
tions table.
Calibration numbers may be causing readings to exceed dis-
play limits. Check calibration number and adjust if necessary.
The console and display may not work below 32º F (0º C). Use an
External Temperature sensor in low-temperature locations or install
the console indoors.
If the console "locks up", reset the console by removing AC and bat-
tery power then restoring power. If this occurs frequently in an AC-
powered console, plug the AC power-adapter into a surge suppres-
sor.
Make sure the console is not near a humidifier or de-humidifier.
Check calibration number and adjust if necessary. If inside humidity
is low, and inside temperature is too high, see "inside temp" below.
Also make sure the console backlight is not on.
For low readings, remove the wind cups and check for friction
sources. Check the anemometer location. Is it sheltered from the
wind? See ISS manual for additional wind speed troubleshooting
information.
The problem may be with the anemometer. Test anemometer by
spinning wind cups. Check fields one-b and two-b on diagnostic
screen and call technical support.
Check calibration numbers for temperature. Remember, dew point
depends on temperature and outside humidity. Make sure they're
working.
G
UIDE
Solution
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vantage pro2 plus

Table of Contents