7.3 Setting of the maximum sensitivity
► Align the sensor so that no light is reflected.
The sensor is to switch when the object is detected
► First press [OUT on], then [OUT off].
The sensor is to switch when the object is not detected
► First press [OUT off], then [OUT on].
7.4 Programming unsuccessful
> The LED flashes quickly, 8 Hz.
• Measured value difference too small.
• Max. programming time of 15 min. exceeded.
7.5 Electronic lock
Lock or unlock the buttons
► Press [OUT on] and [OUT off] simultaneously for 10 s.
> Acknowledgement is indicated by a change of the LED status.

8 Operation

► Check whether the unit operates correctly.
> The LED lights when the switching output is switched.

9 Maintenance, repair and disposal

► Keep the front pane of the sensor free from soiling.
► For cleaning do not use any solvents or cleaning agents which could damage
the plastic material.
► Do not try to open the module enclosure. There are no user - serviceable
components inside.