Liquidyn V10D Controller
Setup (continued)
Use the Push-Button Board to Test the
Controller Operation
The V10D controller functions can be tested using the push-button board.
NOTE: For serial operation, or to incorporate the controller into a special
machine, I/O signals from a PLC can be connected to the Remote input,
instead of to the push-button board. For the Remote input pin assignment,
refer to "Input / Output Connector Pin Assignments" on page 20.
1.
Connect the push-button board to the Remote input on the back of the
controller.
2.
Press the buttons on the push-button board to test the controller
functions. Refer to the tables provided below.
3
2
1
5
4
Item
Push Button
STOP
1
SINGLE SHOT
2
RESET
3
START1 (Start)
4
START2 (Motor)
5
START3 (DIR)
6
START4 (---)
7
18
www.nordsonefd.com info@nordsonefd.com
LED
BUSY
ERROR
COUNTER
7
6
Action
Stops the currently running sequence of steps /shots. Pushing the Start Button re-
starts the sequence of shots at the same position.
Dispenses individual shots (dots) from the valve.
Resets the currently running program to zero.
Runs Program 1. The valve dispenses as programmed.
Runs Program 2. The valve dispenses as programmed.
Runs Program 3. The valve dispenses as programmed.
Runs Program 4. The valve dispenses as programmed.
800-556-3484
Sales and service of Nordson EFD dispensing systems are available worldwide.
Indication
Description
Illuminates
Controller running a
program
Illuminates
Error
Flashes
Square-shaped pulse, 8
ms/shot