Page 1
ProcessMate T10 Temperature Controller Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com...
Page 2
Thank You! You have just purchased the world’s finest precision dispensing equipment. I want you to know that all of us at Nordson EFD value your business and will do everything in our power to make you a satisfied customer.
Using the Auto-Tuning Feature ..........................18 Entering an Alarm Setting ............................19 Troubleshooting ................................20 Part Numbers ................................20 ProcessMate T10 Temperature Controller .........................20 Compatible Nozzle Heaters ............................20 Replacement Parts ................................21 Technical Data ................................21 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
ProcessMate T10 Temperature Controller Introduction The ProcessMate T10 temperature controller is used to control the nozzle heater for Nordson EFD Liquidyn valves. This manual provides only the basic information needed to place the temperature controller into operation quickly. To make additional adjustments to the settings, refer to the manufacturer's operating instructions: www.nordsonefd.com/KT4TempController...
Hot surfaces! Avoid contact with the hot metal surfaces of heated components. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson EFD equipment will be voided if instructions for installation, operation, and service are not followed. If the equipment is used in a manner not specified by Nordson EFD, the protection provided by the equipment may be impaired.
• Test: Verify the operation of features and the performance of equipment using the appropriate sections of this manual. Return faulty or defective units to Nordson EFD for replacement. • Use only replacement parts that are designed for use with the original equipment. Contact your Nordson EFD representative for information and advice.
Disconnect and lock out system electrical power. If using hydraulic and pneumatic shutoff valves, close and relieve pressure. For Nordson EFD air-powered dispensers, remove the syringe barrel from the adapter assembly. For Nordson EFD electro-mechanical dispensers, slowly unscrew the barrel retainer and remove the barrel from the actuator.
• Operate heaters only within the approved temperature range. Refer to "Specifications" on page 11. • Use only heaters that are distributed by Nordson EFD specifically for this micro-dispensing valve. • Do not subject the valve needle to force, knocks, or impact.
Housing Aluminum Ambient operating Temperature: 0–40° C (32–104° F) conditions Humidity: 10–80% Storage temperature: 10–60° C (50–140° F) Product classification IP40 Protection Class III Approvals www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Use this section in tandem with any other system component operating manuals to install all components of the system. Unpack the System Components ProcessMate T10 temperature controller Power cord and power supply (external power adapter) www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
During the self test, all outputs and indicators are turned off. The control procedure starts only after successful diagnosis. Process (PV) and set (SV) values are displayed. Nozzle heater cable Power supply Output: 24 VDC, 3.75 Amp www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Switches between parameters and saves the setting. OUT/OFF key Switches the temperature controller ON or OFF. Down key Reduces the numeric value. Up key Increases the numeric value. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
If the A1 alarm output is activated, this indicator turns red. If the A2 alarm output or the heating current alarm output is enabled, EVT2 Event 2 this light turns red. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
If needed, procedures for auto-tuning and setting the alarm are also provided. NOTE: To make additional adjustments to the settings, refer to the manufacturer's operating instructions: www.nordsonefd.com/KT4TempController www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Press the UP or DOWN ARROW to adjust the value. Press MODE to save the setting. The display returns to the Home screen and shows the new temperature setpoint. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Press MODE to save the setting. Wait while the system auto-tunes itself. AT flashes during auto-tuning. When the display returns to the Home screen, auto- tuning is complete. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Press MODE to save the selection. The display returns to the Home screen. When an alarm is triggered, the EVT1 indicator flashes. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
(opens) an isolated contact (open) and can thus transmit the alarm state to a higher-level controller. Outputs Inputs Assignment Assignment Alarm Output 1 24 VDC input Alarm Output 2 Not connected Not connected Not connected +24 VDC Alarm www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Page 22
NORDSON EFD ONE YEAR LIMITED WARRANTY Nordson EFD products are warranted for one year from date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions.
Need help?
Do you have a question about the ProcessMate T10 and is the answer not in the manual?