Technical Data; Input / Output Connector Pin Assignments - Nordson EFD Liquidyn V10D Operating Manual

Table of Contents

Advertisement

Liquidyn V10D Controller

Technical Data

Input / Output Connector Pin Assignments

• All inputs and outputs are electrically separated.
• The controller is actuated by a 24V I/O signal at the Remote input. The
controller reacts to every square-shaped pulse (raising edge at least 2 ms.)
• Refer to "Use the Push-Button Board to Test the Controller Operation" on
page 18 to test the Remote I/O using the push-button board.
Pin
Direction
1
Output
2
NC
3
Input
4
Input
5
Input
6
Input
7
Input
8
Input
9
Input
10
Output
11
Output
12
Output
13
Output
14
NC
15
Input
16
Input
17
Input
18
Input
19
Input
20
Input
21
Input
22
Output
23
Output
24
Output
25
NC
20
www.nordsonefd.com info@nordsonefd.com
Assignment
Description
+24 VDC Out;
Operating voltage
max. 0.25 A
Not assigned
+ START1
Starts Program 1
+ STOP
Stops
+ SINGLE SHOT
Single shot mode, valve
+ RESET
Counter / reset steps
+ START2
Starts Program 2
+ START3
Starts Program 3
+ START4
Starts Program 4
+ BUSY
Busy
+ ERROR
Error notice (ON = No error)
+ COUNTER
Counter
- 24V (GND) Out
Operating voltage
Not assigned
- START1
- STOP
- SINGLE
- RESET
- START2
- START3
- START4
- BUSY
- ERROR
- COUNTER
Not assigned