Advertisement

Quick Links

Liquidyn V10D Controller
Operating Manual
Electronic pdf files of Nordson EFD
manuals are also available at
www.nordsonefd.com

Advertisement

Table of Contents
loading

Summary of Contents for Nordson EFD Liquidyn V10D

  • Page 1 Liquidyn V10D Controller Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com...
  • Page 2 Thank You! You have just purchased the world’s finest precision dispensing equipment. I want you to know that all of us at Nordson EFD value your business and will do everything in our power to make you a satisfied customer.
  • Page 3: Table Of Contents

    Part Numbers ................................19 Troubleshooting ................................19 Technical Data ................................20 Input / Output Connector Pin Assignments .......................20 Input / Output Wiring Diagrams ..........................21 Power Supply Input Pin Assignments ........................21 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 4: Introduction

    Program parameters can be set and adjusted via a 24V USB interface. Once entered into the controller, programs can be retrieved by an I/O signal. The V10D controller is suitable for incorporation into production line machinery. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 5: Nordson Efd Product Safety Statement

    Hot surfaces! Avoid contact with the hot metal surfaces of heated components. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 6: Halogenated Hydrocarbon Solvent Hazards

    Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 7: Intended Use

    Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson EFD equipment will be voided if instructions for installation, operation, and service are not followed. If the equipment is used in a manner not specified by Nordson EFD, the protection provided by the equipment may be impaired.
  • Page 8: Fire Safety

    • Test: Verify the operation of features and the performance of equipment using the appropriate sections of this manual. Return faulty or defective units to Nordson EFD for replacement. • Use only replacement parts that are designed for use with the original equipment. Contact your Nordson EFD representative for information and advice.
  • Page 9: Important Disposable Component Safety Information

    Disconnect and lock out system electrical power. If using hydraulic and pneumatic shutoff valves, close and relieve pressure. For Nordson EFD air-powered dispensers, remove the syringe barrel from the adapter assembly. For Nordson EFD electro-mechanical dispensers, slowly unscrew the barrel retainer and remove the barrel from the actuator.
  • Page 10: Equipment-Specific Safety Information

    Nordson EFD Product Safety Statement (continued) Equipment-Specific Safety Information The following safety information is specific to the Liquidyn V10D controller. CAUTION Do not dry cycle the valve! The valve can be damaged if it is operated without fluid, causing leakage and a poor seal.
  • Page 11: Specifications

    WEEE Directive This equipment is regulated by the European Union under WEEE Directive (2012/19/EU). Refer to www.nordsonefd.com/WEEE for information about how to properly dispose of this equipment. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 12: Operating Features

    Jet Valve 3-pin M8, valve power input cable connection RS 232 9-pin Sub-D (COM) to USB cable connection Remote 25-Pin Sub-D — remote input / output connection www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 13: Installation

    Unpack the System Components Liquidyn V10D controller Power cord and power supply (external power adapter) USB-to-RS 232 (COM) adapter cable and driver software Push-button board for testing www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 14: Install The Controller And Test The Operation

    Connect the USB-to-RS232 adapter cable to the V10D controller and to the PC. Continue to "View or Change Parameters" on page 15 to view or change the V10D controller settings using the V10D software. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 15: View Or Change Parameters

    Open Devices and Printers > Device Manager. Open Inputs (COM & LPT). It should read "Prolific USB-to-Serial Com Port" and in brackets "COM" with a number. Select this COM port. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 16: About The V10D Controller Parameters

    Single shot imp. time 0.1 to 10,000 ms • Sets how long the air nozzle remains open after the valve is closed. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 17: Pulse Time Setting For Jet-Type Valves

    (Pulse Time) by a factor of 5 to 10. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 18: Use The Push-Button Board To Test The Controller Operation

    Runs Program 2. The valve dispenses as programmed. START3 (DIR) Runs Program 3. The valve dispenses as programmed. START4 (---) Runs Program 4. The valve dispenses as programmed. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 19: Part Numbers

    If the V10D controller is incorporated into a PLC and the valve is not dispensing properly, check all parameters using the push-button board (refer to "Use the Push-Button Board to Test the Controller Operation" on page 18). If the parameters cannot be checked with the push-button board, contact your Nordson EFD representative. www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 20: Technical Data

    Input - SINGLE Input - RESET Input - START2 Input - START3 Input - START4 Output - BUSY Output - ERROR Output - COUNTER Not assigned www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 21: Input / Output Wiring Diagrams

    Power Supply Input Pin Assignments Assignment Description Not assigned +24 VDC Operating voltage Not assigned Not assigned -24V (GND) Operating voltage (ground) Not assigned Not assigned www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 22 NORDSON EFD ONE YEAR LIMITED WARRANTY Nordson EFD products are warranted for one year from date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions.

Table of Contents