Table of Contents

Advertisement

Quick Links

Toµch
PICO
Series Controllers
Operating Manual
Models Included:
• PICO Toµch
• PICO Toµch-XP
Electronic pdf files of Nordson EFD
manuals are also available at
www.nordsonefd.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PICO Touch Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nordson EFD PICO Touch Series

  • Page 1 Toµch PICO Series Controllers Operating Manual Models Included: • PICO Toµch • PICO Toµch-XP ™ Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com...
  • Page 2 Thank You! You have just purchased the world’s finest precision dispensing equipment. I want you to know that all of us at Nordson EFD value your business and will do everything in our power to make you a satisfied customer.
  • Page 3: Table Of Contents

    Adjusting the LCD and Beep Settings ........................42 Calibrating the LCD ..............................42 Setting the Language ..............................43 Viewing the Controller and Valve Information ......................43 Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 4 Adjusting a Wave Profile on the Toµch XP Controller ....................72 Alarm Code Troubleshooting on the Toµch XP Controller ..................73 Toµch XP Controller Part Number ..........................75 Toµch XP Valve Extension Cables ..........................75 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 5: Introduction

    Pµlse XP valve. Refer to the Pµlse valve operating manual for detailed information on the valve. NOTE: Nordson EFD also offers the PICO Toµch XP (Extreme Precision) controller, for use with the PICO Pµlse XP valve. This jetting system is designed for applications that require extremely precise, repeatable micro-deposits where strict tolerances or deposit definition must be met.
  • Page 6: Nordson Efd Product Safety Statement

    Hot surfaces! Avoid contact with the hot metal surfaces of heated components. If contact can not be avoided, wear heat-protective gloves and clothing when working around heated equipment. Failure to avoid contact with hot metal surfaces can result in personal injury. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 7: Halogenated Hydrocarbon Solvent Hazards

    Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 8: Intended Use

    Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson EFD equipment will be voided if instructions for installation, operation, and service are not followed. If the equipment is used in a manner not specified by Nordson EFD, the protection provided by the equipment may be impaired.
  • Page 9: Fire Safety

    • Test: Verify the operation of features and the performance of equipment using the appropriate sections of this manual. Return faulty or defective units to Nordson EFD for replacement. • Use only replacement parts that are designed for use with the original equipment. Contact your Nordson EFD representative for information and advice.
  • Page 10: Important Disposable Component Safety Information

    Disconnect and lock out system electrical power. If using hydraulic and pneumatic shutoff valves, close and relieve pressure. For Nordson EFD air-powered dispensers, remove the syringe barrel from the adapter assembly. For Nordson EFD electro-mechanical dispensers, slowly unscrew the barrel retainer and remove the barrel from the actuator.
  • Page 11: Equipment-Specific Safety Information

    • In the case of damage to the piezo actuator or the Toµch controller, the valve may transition from a CLOSED to an OPEN condition, which can cause fluid release. Nordson EFD recommends continually monitoring the status signal of the Toµch controller and immediately and automatically bleeding the fluid reservoir if these signals indicate an error.
  • Page 12: Specifications

    WEEE Directive This equipment is regulated by the European Union under WEEE Directive (2012/19/EU). Refer to www.nordsonefd.com/WEEE for information about how to properly dispose of this equipment. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 13: Operating Features

    USB port (for PC communication) Nordson EFD Fuse use only I/O 2 port (includes RS-232 terminals) DC power input I/O 1 port Ground terminal VALVE communication connection (5-pin) www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 14: Installation

    Connector, I/O, 15 position, D-sub Power supply, Toµch controller, 1 m (3.3 ft) PICO Pµlse valve (ordered separately) (standard Pµlse valve shown) Extension cable (optional) (Not shown) Quick start guide www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 15: Install The Valve And Controller

    (bare). Attach the opposite end of the ground wire to a permanent earth ground using toothed washers or a toothed lug. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 16 Referring to the guidelines below, install the Pµlse valve on the dispensing equipment: • Nordson EFD strongly recommends using a valve mounting bracket. There are multiple mounting holes to allow for adjustment. Some valve mounting examples are shown below.
  • Page 17 15-position D-sub and backshell are provided. A cable for the 25-pin D-sub connection is customer-supplied. NOTE: Nordson EFD recommends using the analog temperature output (I/O 1, pin 11) to provide operators with appropriate identification and protection against contact when the valve temperature exceeds +45°...
  • Page 18 The system dispenses 10 deposits and displays the frequency (FREQ) indication on the VALVE screen. Make parameter adjustments until the desired deposit result is achieved. Use caution not to exceed maximum frequency ranges. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 19: User Interface

    Title bar blinks red anytime an alarm condition is detected, regardless of the alarm type. Touch the title bar to view the alarm. Example of the alarm screen www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 20: Buttons And Icons

    A system refresh occurs upon power on or when settings are changed remotely. When the system refreshes, an hourglass appears on the touchscreen and no user input is accepted. Refresh takes just a few seconds. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 21: Entering Values

    (increments Example of a numeric data entry screen vary based on the setting being modified) UNDERSCORE Example of an alphabetic data entry screen www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 22: Flowchart Of Menu Structure

    PASSWORDS SYSTEM LOCKOUT RESET RESET SYSTEM HEATER VALVE WAVE PARAMETERS RESET MODE MODE STROKE PASSWORDS SETTING PULSE CLOSE CALENDAR CLOCK CYCLE OPEN COUNT CLOSE VOLTS POWER www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 23: Home Screen

    NOTE: The VALVE screen differs on the Toµch XP controller. Refer to “Toµch XP VALVE Screen” on page 69. Opens the HEATERS screen. Refer to “HEATERS Screen” on page 26. HEATERS www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 24: Valve Screen (Standard Toµch Controller)

    Sets the amount of time between deposits (in milliseconds). Default: 30 (ms) Range: 2 (ms) to 9.9999 (s) typical (minimum setting depends on open and close profile times) Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 25 “Changing the System (VALVE) Operating Mode” on page 33 for more detailed information. (CYCLE) NOTE: The CYCLE icon: • Is present only on the VALVE screen. • Is disabled if an alarm condition exists. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 26: Heaters Screen

    If toggled on, shows the actual temperature of the piezo actuator stack. Refer to the SYSTEM screen parameters under “SYSTEM Screens” on page 32 to toggle the STACK display. (Non-editable) www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 27: Wave Profile Screen

    Two pre-programmed wave profiles (RAMP and SMOOTH) are included. RAMP is the default wave profile. Up to four additional custom wave profiles can be created by Nordson EFD. Contact your Nordson EFD technical support representative for assistance.
  • Page 28: Wave Parameters Screen (Standard Toµch Controller)

    When pressed on this screen, the Wave Profile icon opens the WAVE PROFILE screen, on which you can select a different wave profile. Refer to “WAVE PROFILE Screen” on page 27 for details. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 29: Settings Screen

    Sets the user interface language. Refer to the SET LANGUAGE screens for available languages. LANGUAGE NOTE: For screen captures, refer to “Setting the Language” on page 43. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 30: Lcd Set Screen

    Sets the touchscreen brightness (25–100%). CALIBRATE TOUCH Opens the LCD calibration screen. DISPLAY BEEP Enables or disables the button-press beep sound. BEEP LEVEL Sets the button-press beep volume (5–100 %). www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 31: Function Lockout Screen

    NOTE: Changing the LOCKOUT password AND also enabling the SYSTEM lockout removes required for the ability to perform an emergency password reset. Contact Nordson EFD Technical Services access) if you forget your custom LOCKOUT password and you have enabled the SYSTEM lockout.
  • Page 32: System Screens

    Forces a reset of the LCD and re-initiates communication with the controller. All settings return their factory default values. Performing a reset causes an LCD fault alarm. More... Toggles between the two system screens. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 33: Setup And Programming Procedures

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 34: Adjusting The Valve Operating Parameters (Pulse, Cycle, Or Count)

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 35: Switching The Heater Control (Mode) To On, Off, Or Remote

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 36: Connecting A Controller Status Monitoring Signal

    Toµch controller, the valve may transition from a CLOSED to an OPEN condition, which can cause fluid release. Nordson EFD recommends continually monitoring the status signal of the Toµch controller and immediately and automatically de-pressurizing the system if the signal indicates an error. Follow this procedure to connect a controller status monitoring signal.
  • Page 37: Managing The Wave Profile

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 38: Adjusting A Wave Profile (Standard Toµch Controller)

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 39: Viewing Or Changing System Settings

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 40: Managing Password Protection

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 41: Managing Lockouts

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 42: Adjusting The Lcd And Beep Settings

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 43: Setting The Language

    CALENDAR WAVE ABOUT OK (check) LANGUAGE CLOCK SET PARAMETERS Backspace Cancel HEATERS LOCKOUTS SETTINGS LCD SETTINGS Decimal Point HOME PASSWORDS SYSTEM CYCLE Decrement Increment PURGE VALVE www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 44: Operation

    HEATERS icon and then press ON to switch the HEATERS mode to On. NOTE: Upon reboot, the controller remembers the last selected HEATERS mode. Switching on heater control www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 45: Purging The System

    Press the VALVE > PURGE icons as needed to clear debris or after changing the fluid body assembly. Refer to the valve operating manual for more detailed information on purging and system cleaning. Purging the system www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 46: Clearing Alarms

    If needed, correct the problem that caused the alarm. Refer to “Troubleshooting” on page 49 for complete troubleshooting information, including a list of all system alarms, causes, and corrective actions. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 47: Routine Shutdown

    2 m (6.6 ft) valve extension cable set 7361299 6 m (19.7 ft) valve extension cable set 7361300 9 m (29.5 ft) valve extension cable set www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 48: Replacement Parts

    B male, 2 m (6.6 ft) 7361296 Kit, power supply 7361297 Kit, fuse, T, 5.0 Amp, 250V, 5 X 20 mm, 10 pc. Filter 7361363 Kit, inlet filter www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 49: Troubleshooting

    EFD representative for the battery replacement unresponsive instructions. NOTE: The battery powers only the real-time clock. Its removal or replacement will not affect any functions. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 50: Alarm Code Troubleshooting

    LCD Communication Controller Problem occurred with LCD display: Loss • Return the controller to Nordson EFD or to the vendor for service. Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 51 If the alarm persists, return the controller to Nordson EFD or to the vendor for service. Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 52 If the alarm persists, return the controller to Nordson EFD or to the vendor for service. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 53: Technical Data

    NOTE: Use the remote communication capability to change the target temperature window. Refer to the "trng" command in the "Temperature" table in “Appendix A, Remotely Operating the Controller” on page 60. Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 54 NOTE: This signal is active only when the valve POWER is ON. Refer to “POWER” on page 25 to understand how the valve is powered ON or OFF. Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 55: I/O 2 25-Position D-Sub

    0–5V Transmission pin for RS232. Contains response data from controller. Not available Nordson EFD use only Not available Nordson EFD use only Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 56 Use the “dioe”and “dioi” commands to configure the functionality of this pin (Refer to “Appendix A, Remotely Operating the Controller” on page 60). Contact Nordson EFD for applications which require more than 200 mA. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 57: Wiring Diagrams

    Temperature OFF Pin 1 Analog Temp In (0–10V) 0–10V Analog 0–10V Analog Signal Temperature In Temperature Pin 2 & 10 Analog Gnd Analog Ground Analog Ground www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 58: Pico Toμch Controller Outputs

    +24V Pin 4 IO GND Pin 11 Analog In Temp Out Analog Temperature Out 0–10V Temperature Pin 2 & 10 Analog GND Analog Gnd Analog GND www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 59: Pico Toμch Controller And Pico Controller 2+2-Xch-V3

    Pin 4 Pin 15 current output of 200 mA. 24 V_IO +24V IO Pin 5 IN 1 Pin 14 IN 10 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 60: Appendix A, Remotely Operating The Controller

    • The <3 acknowledge command is removed from the examples since all commands are successfully evaluated. • The return constant (Enter key: ↵) is depicted as [Enter] in all examples. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 61 Stroke..: 0070 Up Ramp Time.: 000.500ms Dwn Ramp Time: 000.250ms Close Voltage: 090 Numb Shots...: 0000398174 Power Mode: ON at boot up Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 62 0002.23,0005.77,00535sdr1 [Enter] COUNT in one command 0002.23,0005.77,00535 Where xxxx.xx is the OPEN time (in ms) Where yyyy.yy is the CLOSE time (in ms) Where zzzzz is COUNT www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 63 • Temperature must be entered in °C. Reads the adjustable rrng [Enter] rrng rrng temperature range limit Temp Range = 06.0C for I/O 1 pin 5 (Status of Temperature) www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 64 Refer to dvrf under “Valve 2cfg2 [Enter] (Driver)” on page 61. Input Configuration... Pin 6 = Error Reset Pin 12 = Valve Purge Control Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 65 • I/O 1 pin 4 (GND) and pin 15 (Ext 24 Volts) • I/O 2 pins 17, 19, and 21 (DSUB_GND) and pin 25 (+25). www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 66 (active alarms) Alarm:0x90 as a bitmap or SYS OK when there are no stat [Enter] alarms SYS OK arst Resets a currently arst arst [Enter] active alarm www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 67: Appendix B, Toµch Xp Controller

    Toµch XP controller. • On the Toµch XP VALVE screen only, the frequency indication displays under the cycle time. PICO Toµch XP controller and Pµlse XP valve www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 68: Toµch Xp Operating Features

    USB port (for PC communication) Nordson EFD Fuse use only I/O 2 port (includes RS-232 terminals) DC power input I/O 1 port Ground terminal VALVE communication connection (6-pin) www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 69: Toµch Xp Valve Screen

    NOTE: For an explanation of all elements on the VALVE screen, refer to “VALVE Screen (Standard Toµch Controller)” on page 24. Location of the frequency indications on a Toµch XP controller www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 70: Toµch Xp Wave Parameters Screen

    When pressed on this screen, the Wave Profile icon opens the WAVE PROFILE screen, on which you can select a different wave profile. Refer to “WAVE PROFILE Screen” on page 27 for details. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 71: Routine Startup For A Toµch Xp And Pµlse Xp System

    Switching on heater control Press the VALVE icon and then MODE until the touchscreen shows the desired operating mode. Placing a Toµch XP system in the Continuous mode www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 72: Adjusting A Wave Profile On The Toµch Xp Controller

    Adjusting the STROKE setting of the enabled wave profile (Toµch XP controller) Press HOME to save the settings and return to the HOME screen. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 73: Alarm Code Troubleshooting On The Toµch Xp Controller

    Valve Response Controller has received more communication Mismatch signals from the valve than expected: • Check the valve cables for interference (EMI). Continued on next page www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 74 • Ensure that the heater body the houses the fluid body assembly is fully closed. Zero Ramp Time Settings Return the valve to Nordson EFD or to the vendor for service. www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 75: Toµch Xp Controller Part Number

    6 m (19.7 ft) valve extension cable set, Toµch XP 7365313 9 m (29.5 ft) valve extension cable set, Toµch XP 12 m (39.4 ft) valve extension cable set, Toµch XP 7365314 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
  • Page 76 Nordson EFD be liable for incidental or consequential damages. This warranty is valid only when oil-free, clean, dry, filtered air is used, where applicable. For Nordson EFD sales and service in over 40 countries, contact Nordson EFD or go to www.nordsonefd.com.

This manual is also suitable for:

Pico touch-xp

Table of Contents