Error Detected By Brake Board - Technogym Recline Forma Service Maintenance Manual

Hide thumbs Also See for Recline Forma:
Table of Contents

Advertisement

6.4. ERROR DETECTED BY BRAKE BOARD

When the brake board detects an error, it stops and interrupts the power supply to the brake
winding, and an error code identifying the fault condition is shown on the display and saved in the
error history log. When this error is received by the digital plan board, it halts the exercise and
shows the "THE EQUIPMENT IS BLOCKED" message on the display.
The errors logged by the brake board can also be viewed from the machine keyboard as described in
paragraph 9.2.4. "Errors log".
The following paragraphs describe the troubleshooting procedures for these three cases.
6.4.1.
E
1
RROR
This code indicates an overheating error: this condition occurs when the temperature detected by the
sensor on the circuit board exceeds 90°C.
Try switching the machine off for 1 hour. If it resumes working correctly, the machine probably
overheated as a result of intensive use. If, on the other hand, the error persists, it is necessary to
replace the brake board.
6.4.2.
E
2
RROR
This code indicates an overcurrent error: this condition occurs when the current going to the
solenoid measured by the board exceed the max value
This error is caused by an HW problem on the brake board or a short circuit on the solenoid. To
solve the problem, it is necessary to replace the brake board or the solenoid.
Page 6.8
ERROR DETECTED BY
BRAKE BOARD
Check the error code
stored in memory
ON BRAKE BOARD
ON BRAKE BOARD
RECLINE EXCITE: Service & Maintenance Manual - rev. 1.1
Error 1
Error 2
Error 4
Error 8
Error 16 - 32
Error 128

Advertisement

Table of Contents
loading

Table of Contents