INSTALL SHEET
Sensitivity adjustment
The OSMVC detector comes with the capability of adjusting the sensitivity level of the PIR. It can improve the
detection or, on the contrary, reduce false alarms. Raising sensitivity will raise detection range, the detection
field will be larger and smaller thermal signatures will be detected. You should only use this feature when the
site has been diagnosed as needing this adjustment. It cannot be used to optimize detection as the adjustment
may be too high and generate either false alarms or missed intrusions.
Examples : Plant growth, pets.
Please note that the detector must be installed to prevent intrusions (aim the detector towards an access
point), sensitivity adjustment will have no effect if the installation doesn't comply with the installation
recommendations described in this document.
Adjust sensitivity for the OSMVC MotionViewer
To change the OSMVC sensitivity, you need to change the detector name:
Enter the detector name then enter the $ symbol at the end and the chosen digit
(without space). The number following $ will depend on the necessary adjustment:
$ Symbol
CMA keypad : Press @ repeatedly until $ is displayed
XMA/XMB keypad : Press 1 repeatedly until $ is displayed
OSMVC OUTDOOR STREAMING MOTION VIEWER
CONFIGURATION
CHANGE NAME
MINIMAL
SENSITIVITY
LOW SENSITIVITY
DEFAULT
SENSITIVITY
HIGH SENSITIVITY
MAXIMAL
SENSITIVITY
DEVICE
To select the OSMVC
OK or YES
DEVICE
OK or YES
SENSITIVITY
ADJUSTMENT
detector_name$2
detector_name$1
detector_name
detector_name$8
detector_name$9
6
Need help?
Do you have a question about the OSMVC 200 and is the answer not in the manual?