Information LEDs

34
Lenovo ThinkSystem NE2552E Flex Switch: Installation Guide
The front panel of the switch has LEDs for system and port status. The Power, 
Locator, and Error LEDs indicate the switch status. The Link (LINK) and Activity 
(TX/RX) LEDs indicate the status of the external ports.
Notes:
A yellow LED on the Lenovo Flex System chassis is lit when a system error or 
event has occurred. To identify the error or event, check the Lenovo Flex System 
management‐module event log or the switch system log.
During POST, the switch Power LED continuously flashes. Additionally, all of 
the switch status LEDs and the licensed Port LEDs are lit as a visual indication 
they are working. Once POST has successfully completed, the switch Power 
LED remains on and the switch Error LED is off.
Any errors that are detected during POST are written to the system log. For 
information about the command to read the system log, see the Command Reference 
for the switch.
When POST errors are written to the system log, these errors are also written to the 
Lenovo Flex System management‐module event log. If a hardware error, such as a 
current fault occurs, the CMM displays it. If a firmware error occurs, the CMM 
displays the Module did not complete POST message and a post error code that 
indicates the test that was running when the error was detected.
Note: You can also use the CMM to make sure that the switch is operating 
correctly. For more information, see the CMM documentation.