Post Errors - Lenovo ThinkSystem NE2552E Installation Manual

Flex switch
Hide thumbs Also See for ThinkSystem NE2552E:
Table of Contents

Advertisement

POST Errors

1. Log on to the CMM Command‐Line Interface (CLI) as described in the CMM 
documentation. If necessary, obtain the Internet Protocol (IP) address of the CMM 
from your system administrator. The login window opens.
2. Turn off the power to the switch; then, turn it on again.
3. After POST is completed, the CMM displays the results. Refresh the window to 
view the POST results. If a critical error occurs, replace the switch. If a noncritical 
error occurs, see the switch error log for additional details.
© Copyright Lenovo 2018
There are two types of errors: noncritical and critical. A noncritical error applies to 
one port, and the switch is operational. You can continue to operate the switch; 
however, you must replace it as soon as possible. When critical errors occur, the 
switch does not operate.
To view POST results, complete the following steps:
The following table describes the basic critical and noncritical failures. This 
abbreviated list is representative; it is not an exhaustive list. An error code is 
associated with each failure. Error codes are displayed on the CMM Switch 
Information window. Be sure to note the applicable error code and corresponding 
failure. You might have to provide this information when you call for service. For 
details, see "Getting Help and Technical Assistance" on page
Diagnostic
Failing functional area
indicator (in hex)
00–7F
Base internal functions
80–9F
Internal interface failures
A0–AF
External interface errors
B0–FE
Reserved
FF
Switch "good" indicator
55.
Failure criticality
Critical
Noncritical
Noncritical
Noncritical
Operation
Chapter 5: Solving Problems