TECHNICAL DATA

Mains voltage
Fuse (delayed- -action)
Primary current I
max
Primary current I
eff
Voltage/current range (DC)
Maximum permissible load at
25% duty cycle
35% duty cycle
60% duty cycle
100% duty cycle
Power factor at maximum current
Efficiency at maximum current
Open- -circuit voltage
Operating temperature
Constant A- -weighed sound pressure
Dimensions, l x b x h
Weight
Enclosure class
Application class
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.

WIRING DIAGRAM

The power source consists of a number of function modules, which are described in the
component descriptions on the following pages. Wire numbers and component names in
the wiring diagrams show to which module each component belongs.
Wires/cables within modules are marked 100 -- 6999.
Circuit boards within each module have names such as 20AP1 -- 20AP99.
15
= module association, 1--69
AP = circuit board
1
= individual identification number, 0--99
Components within modules -- are named in a similar way.
ch25d1
230 V ±10% 1µ 50/60 Hz
16 A
36 A
21 A
8 A / 20 V -- 150 A / 26 V
150 A / 26 V
140 A / 25.
V
5
110 A / 24.
V
5
90 A / 23.
V
5
0.62
77%
58 -- 75 V
--10˚C -- +40˚ C
< 70 db
380 x 180 x 300 mm
8 kg
IP23C
- - 4 - -
Edition 040830