Default Values - Datalogic CATCHER D531 Series Quick Reference

Table of Contents

Advertisement

CATCHER™ D531 SERIES

DEFAULT VALUES

USB DEFAULT SETTINGS
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, character replacement disabled.
: USA keyboard, inter-character and inter-code delays disabled,
USB KEYBOARD
control character emulation = ctrl+shift+key.
: no handshaking, delay disabled, rx timeout 5 sec., ack/nack disabled,
USB COM
serial decode control = disabled, serial sleep control = disabled.
Default Headers and Terminators for each USB mode:
-
USB-KBD: no header, terminator = ENTER
-
USB-KBD APPLE: no header, terminator = ENTER
-
USB-KBD-ALT-MODE: no header, terminator = CR
-
USB-COM: no header, terminator = CR-LF
-
USB-IBM-TABLE TOP: not applicable
-
USB-IBM-HAND HELD: not applicable
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 5 sec., ack/nack disabled, serial decode control = disabled, serial sleep
control = disabled.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = CR-LF, character replacement disabled.
RS232 Nixdorf DEFAULT SETTINGS
9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking hardware
(RTS/CTS), delay disabled, rx timeout 9.9 sec., ack/nack disabled, serial
decode control = disabled, serial sleep control = disabled.
: code identifier enabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = CR, character replacement disabled.
RS232 Fujitsu DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 2 sec., ack/nack disabled, serial decode control = disabled, serial sleep
control = disabled.
: code identifier enabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = CR, character replacement disabled.
RS232 ICL DEFAULT SETTINGS
9600 baud, parity even, 8 data bits, 1 stop bit, handshaking RTS always on,
delay disabled, rx timeout 9.9 sec., ack/nack disabled, serial decode control =
disabled, serial sleep control = disabled.
: code identifier enabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = CR, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = ENTER, character replacement disabled.
15

Advertisement

Table of Contents
loading

Table of Contents