Salus ST620ROF Instruction Manual page 42

Programmable rf room thermostat with one touch energy saving override control
Table of Contents

Advertisement

Programming
Programming Modes:
Number of Programmes:
Override Facility:
Holiday Facility:
Temperature
Scale:
Tolerance:
Sampling Rate:
Display Range:
Display Resolution:
Set Temperature Range:
Resolution:
Control
Control Method:
Memory Backup
Type:
Radio Frequency (RF) Settings
Operating Frequency:
Max. Operating Range:
Environment
Operating Temperature:
Storage Temperature:
Switching
Switching Voltage:
Switching Current:
Contact Type:
42
ST620ROF INSTRUCTION MANUAL
User selectable for 5/2 or 7 day option
Six (6) user programmes plus factory default programme.
User selectable programme override facility.
User selectable option to temporarily override selected programme.
Celsius
Less than ± 0.5 ºC at 25 ºC
Every 15 seconds
0.0 ºC to + 45.0 ºC
0.5 ºC
5.0 ºC to + 35 ºC
0.5 ºC
1. ON – OFF control
2. PWM control
Electrically Erasable Programmable Read Only Memory (EEPROM)
868 MHz
100 metres (free air) or 30 metres (indoors)
0 ºC to + 50 ºC
- 10 ºC to + 60 ºC
0 - 230V AC / 50Hz
16A resistive, 5A inductive
Volt Free