10-32 Grounding
screw (binding
head) under
motor canopy
115
L2
Volt
B
White w/
Lines
Black Tracer
A
L1
Black
Figure 9 – 115V and 230V Wiring
WARNING
Hazardous voltage. Can
shock, burn, or cause
death.
Ground pump before con-
necting to power supply
Use wire size specified in Wiring Chart (below). If possi-
ble, connect pump to a separate branch circuit with no
other appliances on it.
WIRING
1. Install, ground, wire and maintain pump in accordance with your
local electrical code and all other codes/ordinances that apply.
Consult your local building inspector for local code information.
2. Ground pump permanently using wire of size and type specified
by approved local or national codes.
Risk of explosion. Do not ground to gas
supply line.
RECOMMENDED FUSING AND WIRING DATA – 60 CYCLE MOTORS
Motor
Volts
Horsepower
1/3
115/230
1/2
115/230
3/4
115/230
*Fusetrons recommended for all motor circuits
ELECTRICAL
Top view of
Pressure Switch
L2
L1
Ground
Wire
L2
L1
Ground
Wire
Ground motor before con-
necting to electrical
power supply.
Failure to ground motor
can cause severe or fatal
electrical shock hazard.
Do not ground to a gas
supply line.
To avoid dangerous or
fatal electrical shock, turn
OFF power to motor before
working on electrical connec-
tions.
Supply voltage must be
within ±10% of nameplate
voltage. Incorrect voltage can
cause fire or seriously damage
motor and voids warranty. If in
doubt consult a licensed electri-
cian.
(FIG. 9)
TABLE 1
Branch
Max. Load
Fuse*
Amperes
Rating-Amps
9.4/4.7
15/15
9.4/4.7
15/15
12.2/6.1
20/15
10-32 Grounding
screw (binding
head) under
motor canopy
White w/
230
L2
Black Tracer
Volt
B
Lines
Black
A
L1
3. Connect ground wire first. Connect to ground first, then to green
grounding terminal provided on pressure switch identified as
GRD. Ground connection MUST be made to this terminal. Do
not connect motor to electrical power supply until unit is perma-
nently grounded; otherwise serious or fatal electrical shock haz-
ard may be caused.
4. For best ground connection, connect to grounded lead in service
panel or to metal underground water pipe or well casing at least
10 ft. long. If plastic pipe or insulated fittings are used, run
ground wire directly to metal well casing or use ground electrode
furnished by the power company.
TO CONNECT PRESSURE SWITCH:
Risk of electrical shock. Disconnect power at
service panel before connecting pressure switch to pump. Do
not operate pump unless motor and pressure switch are con-
nected to each other by a solid metal connection and are
grounded.
1. Remove switch cover.
2. Connect green ground wire to terminal in base or side of switch
marked GROUND, GRD, or
minals; connect to either one.
3. Connect power supply leads to switch terminals marked LINE, L,
or L1/L2.
4. Motor leads should be connected at factory to switch terminals
marked LOAD, MOTOR, M or M1/M2. If not, connect them to
switch terminals.
5. Make sure that either:
A. Motor frame is connected to pressure switch by a solid metal
connection, or
B. Motor ground wire is connected to ground terminal in switch.
6. Replace pressure switch cover.
Pump is now wired for operation.
DISTANCE IN FEET FROM MOTOR TO METER
0'
51'
101'
to
to
to
50'
100'
200'
WIRE SIZE (AWG #)
14/14
14/14
12/14
14/14
14/14
12/14
12/14
12/14
10/14
6
Top view of
Pressure Switch
L2
L1
Ground
Wire
L2
L1
Ground
Wire
373 1293
(FIG. 9)
. There may be two ground ter-
201'
301'
to
to
300'
400'
10/12
8/12
10/12
8/12
8/14
6/12
401'
to
500'
8/10
8/10
4/10