Controls and indicators on the plasma power supply

Cutting controls

Status screen – By default, this screen shows system status information. It also
Adjustment knob – Turn this knob to adjust the output current in increments of
Fault LED (yellow) – When this LED is on, it shows that there is a fault condition
Automatic / manual gas pressure setting mode selector – Push and hold
Powermax65/85/105 SYNC
shows fault codes and fault icons when faults occur.
In different modes, this screen changes to show different kinds of
information about the plasma power supply, SmartSYNC torch, and
Hypertherm cartridge.
1 A.
You can also use this knob to increase or decrease the gas pressure. Refer
to
Adjust the gas pressure manually
with the plasma power supply.
This LED also comes on when the torch is set to the yellow lock (X)
position. Refer to
page
this button until the green LED comes on to go into manual gas pressure
mode (approximately 2 seconds). Push the button again to go back to
automatic gas pressure mode. Refer to
Manual gas pressure mode must be used only by
experienced operators.
In some conditions, you can push this button to immediately go from the
screen that you are on to the status screen.
Operator Manual
810470
on page 76.
67.
page
Operate the Plasma System
76.