Do a gas test

Do a gas test to make sure that sufficient gas pressure is coming from the torch.
CHANCE OF BURNS AND CUTS
Point the torch away from you before doing a gas test. Always keep hands, clothes, and objects away
from the torch tip. Never point the torch toward yourself or others.

Start and stop a gas test in automatic gas pressure mode

1. Set the SmartSYNC torch to the green "ready to fire" (
2. Hand torches: Fire the torch 1 time to get the warning puffs of air.
3. Make sure that the correct operating
mode is selected for the process that
you want to examine: Cut mode,
Gouge mode, or Expanded Metal
mode.
4. Push and hold the operating mode
button for 2 seconds until the gas
test screen shows.
Gas flows continuously from the
torch when the plasma power supply
is in gas test mode.
Powermax65/85/105 SYNC
WARNING
Operator Manual
810470
Troubleshoot Common Problems
) position.
Push and hold for 2 seconds.
6