17. Installing a communication
interface module
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply to the motor
and to the signal relay. Wait at least 5
minutes before starting any work on the
motor. Make sure that the power supply
cannot be accidentally switched on.
Always use an antistatic service kit when
handling electronic components. This
prevents static electricity from damaging
the components.
When unprotected, place the component
on the antistatic cloth.
Fig. 31
Antistatic service kit
1. Loosen the four screws (fig. 32, A) and remove
the terminal box cover (fig. 32, B).
A
B
Fig. 32
Removing the terminal box cover
28
2. Remove the CIM cover (fig. 33, A) by pressing
the locking tab (fig. 33, B) and lifting the end of
the cover (fig. 33, C). Then lift the cover off the
hooks (fig. 33, D).
C
B
Fig. 33
Removing the CIM cover
3. Remove the securing screw (fig. 34, A).
A
Fig. 34
Removing the securing screw
4. Fit the CIM module by aligning it with the three
plastic holders (fig. 35, A) and the connecting
plug (fig. 35, B). Press home the module using
your fingers.
A
Fig. 35
Fitting the CIM module
5. Fit and tighten the securing screw (fig. 34, A) to
1.3 Nm.
6. Make the electrical connections to the CIM
module as described in the instructions delivered
with the module.