Grundfos Eye - Grundfos CREC Installation And Operating Instructions Manual

Table of Contents

Advertisement

15. Grundfos Eye

The operating condition of the pump is indicated by
Grundfos Eye on the operating panel. See fig. 30, A.
Fig. 30
Grundfos Eye
Grundfos Eye
26
1
2
Indication
No lights are on.
The two opposite green indicator lights
are rotating in the direction of rotation of
the pump when seen from the non-drive
end.
The two opposite green indicator lights
are permanently on.
One yellow indicator light is rotating in
the direction of rotation of the pump
when seen from the non-drive end.
One yellow indicator light is
permanently on.
The two opposite red indicator lights
flash simultaneously.
The green indicator light in the middle
flashes quickly four times.
The green indicator light in the middle
flashes continuously.
The green indicator light in the middle is
permanently on.
The green indicator light in the middle
flashes quickly while Grundfos GO
Remote is exchanging data with the
pump. It takes a few seconds.
Description
The power is off.
The pump is not running.
The power is on.
The pump is running.
The power is on.
The pump is not running.
Warning.
The pump is running.
Warning.
The pump is stopped.
Alarm.
The pump is stopped.
This is a feedback signal which the
pump gives in order to ensure
identification of itself.
Grundfos GO Remote or another
pump is trying to communicate with
the pump. Press
on the pump
operating panel to allow
communication.
Remote control with Grundfos GO
Remote via radio.
The pump is communicating with
Grundfos GO Remote via radio
connection.
Remote control with Grundfos GO
Remote via infrared light.
The pump is receiving data from
Grundfos GO Remote via infrared
communication.