7. Connect the cable screens of the bus cables to
protective earth via one of the earth clamps (fig.
36, A).
Fig. 36
Connecting the cable screens to
protective earth
8. Route the wires for the CIM module. See the
example in fig. 37.
Fig. 37
Example of wire routing
9. Fit the CIM cover.
10. If the CIM module is supplied with an FCC label,
then place this on the terminal box. See fig. 38.
Fig. 38
FCC label
11. Fit the terminal box cover (fig. 32, B) and
cross-tighten the four mounting screws (fig. 32,
A) to 6 Nm.
18. Changing the position of the
operating panel
A
You can turn the operating panel 180 °. Follow the
instructions below.
1. Loosen the four screws (TX25) of the terminal
box cover.
Fig. 39
FCC
Make sure that the terminal box cover is
aligned with the operating panel. See
section
18. Changing the position of the
operating
panel.
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply to the motor
and to the signal relay. Wait at least 5
minutes before starting any work on the
motor. Make sure that the power supply
cannot be accidentally switched on.
Loosening the screws
29