Changing The Orientation Of The Fluid Inlet And Outlet Ports; Fluid Pressure Relief Valve - Graco Husky 2150 Instructions And Parts List

Air-operated diaphragm pumps
Hide thumbs Also See for Husky 2150:
Table of Contents

Advertisement

Changing the Orientation of the Fluid Inlet
and Outlet Ports
The pump is shipped with the fluid inlet (R) and outlet
(S) ports facing the same direction. See Fig. 4. To
change the orientation of the inlet and/or outlet port:
1. Remove the screws and washers (106, 112, 113
and 114) holding the inlet (102) and/or outlet (103)
manifold to the covers (101).
2. Reverse the manifold and reattach. Install the
screws and washers and torque to 150- 160 in- lb
(17- 18 N•m). See Torque Sequence, page 33.
KEY
N
1/2 npt(f) air inlet port
N
1/2 npt(f) air inlet port
P
Muffler
Air exhaust port is 3/4
npt(f)
R
2" fluid inlet flange
S
2" fluid outlet flange
1
Torque to 150- 160 in- lb (17- 18 N•m). See
Torque Sequence, page 31.
N
P
102
Fig. 4
Tel: 866-777-6060
Fax: 866-777-6383
Installation
101 Fluid covers
102 Fluid inlet manifold
103 Fluid outlet manifold
106 Fluid outlet manifold
screws (top)
112 Fluid inlet manifold screws
(bottom)
113 Fluid outlet manifold
washer
114 Fluid inlet manifold washer
106
103
1
S
113
101
R
114
112
04613 B
1
Springer Pumps, LLC

Fluid Pressure Relief Valve

CAUTION
Some systems may require installation of a
pressure relief valve at the pump outlet to prevent
overpressurization and rupture of the pump or
hose. See Fig. 5.
Thermal expansion of fluid in the outlet line can
cause overpressurization. This can occur when
using long fluid lines exposed to sunlight or ambi-
ent heat, or when pumping from a cool to a warm
area (for example, from an underground tank).
Overpressurization can also occur if the Husky
pump is being used to feed fluid to a piston pump,
and the intake valve of the piston pump does not
close, causing fluid to back up in the outlet line
KEY
R
2" fluid inlet flange
S
2" fluid outlet flange
V
Pressure relief valve
Part No. 112119 (stainless steel)
Install valve between fluid inlet and outlet ports.
1
2
Connect fluid inlet line here.
3
Connect fluid outlet line here.
Fig. 5
Website: www.springerpumps.com
S
3
V
1
2
R
04616B
308550 11
Int'l: +001 267 404 2910

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents