Fluid Supply Line; Fluid Outlet Line; Fluid Inlet And Outlet Ports - Graco Husky 1050HP Operation

2:1 air-operated diaphragm pump
Hide thumbs Also See for Husky 1050HP:
Table of Contents

Advertisement

Fluid Supply
Supply Line
Line
Fluid
Fluid
Supply
Line
See
Typical Floor Mount Installation, page 12
1. Use grounded flexible, fluid supply hoses (G).
See
Grounding, page 8
2. If the inlet fluid pressure to the pump is more
than 25% of the outlet working pressure, the ball
check valves will not close fast enough, resulting
in inefficient pump operation.
3. Excessive inlet fluid pressure also will shorten
diaphragm life. Approximately 3 - 5 psi (0.02-
0.03 MPa, 0.21-0.34 bar) should be adequate
for most materials.
4. For maximum suction lift (wet and dry), see
Technical Data, page
always install the pump as close as possible to
the material source.
334014D
.
20. For best results,
Fluid Outlet
Outlet Line
Line
Fluid
Fluid
Outlet
Line
See
Typical Floor Mount Installation, page
1. Use grounded, flexible fluid hoses (L). See
Grounding, page 8
2. Install a fluid drain valve (J) near the fluid outlet.
3. Install a shutoff valve (K) in the fluid outlet line.
Fluid Inlet
Fluid
Fluid
Inlet and
Inlet
and
and Outlet
Outlet Ports
Outlet
NOTE:
NOTE:
NOTE: Remove and reverse the manifold(s) to
change the orientation of inlet or outlet port(s). Follow
Torque Instructions, page
1050HP — — — Aluminum
1050HP
1050HP
Aluminum Manifolds
Aluminum
Manifolds
Manifolds
The fluid inlet and outlet manifolds each have two 1
in. npt(f) or bspt threaded ports (M, N). Close off the
unused port using the supplied plugs.
1050HP — — — Stainless
Stainless Steel
Steel Manifolds
1050HP
1050HP
Stainless
Steel
The fluid inlet and outlet manifolds each have one
1 in. npt(f) or bspt port.
Installation
12.
.
Ports
Ports
16.
Manifolds
Manifolds
11