Event
Event Level
Event
Code
Code
Code
F2DP
Deviation
F2DT
Deviation
K4E0
Alarm
K6EH
Alarm
K9EH
Deviation
L3X0
Deviation
L4X0
Alarm
MA01
Advisory
MA02
Advisory
MA03
Advisory
T3E0
Deviation
T4C0
Alarm
T4E0
Alarm
3A3167N
Tel: 866-777-6060
Fax: 866-777-6383
Level
Level
Description
Description
Description
The motor control limit has been
reached and Max Power Mode is
enabled in menu G204. The controller
is at maximum line current, maximum
motor current, or maximum output
voltage, but the motor will continue to
run at a reduced performance.
The motor temperature is above
120°C (248°F) and Max Power Mode
is enabled in menu G204. The output
current is being limited, but the system
will run at a reduced performance.
The motor speed has exceeded the
maximum.
The position sensor has read an
invalid position, likely because it is not
connected.
Position errors (skips, momentary
invalid positions) have been detected.
Likely due to noise on the motor
feedback cable.
The pump leak sensor has detected
a leak and the Pump Leak Type is
set to Deviation in G206. The pump
continues to run.
The pump leak sensor has detected a
leak and the Pump Leak Type is set to
Alarm in G206. The pump has been
stopped.
The maintenance pump cycles have
exceeded the number set on menu
G230.
The maintenance pump cycles have
exceeded the number set on menu
G231.
The maintenance pump cycles have
exceeded the number set on menu
G232.
The internal motor temperature is
above 100°C (212°F).
The internal IGBT module temperature
has exceeded the limit of 100°C
(212°F).
The internal motor temperature is
above 150°C (302°F) and Max Power
Mode is disabled in G204.
Springer Pumps, LLC
Troubleshooting the Graco Motor Control
Solution
Solution
Solution
Reduce pump flow/pressure.
Reduce pump flow/pressure or duty
cycle.
Event will clear after acknowledgment.
Check operating conditions to
determine the source of the alarm.
Ensure the feedback cable is correctly
installed and away from any external
noise sources.
Ensure the feedback cable is correctly
installed and away from any external
noise sources.
Replace worn parts to stop leak, drain
leak sensor and replace.
Replace worn parts to stop leak, drain
leak sensor and replace.
Clear the Maintenance Counter (menu
G130).
Clear the Maintenance Counter (menu
G131).
Clear the Maintenance Counter (menu
G132).
Reduce pump flow or duty cycle.
Reduce power output or decrease
ambient temperature.
Reduce pump flow or duty cycle.
Enable Max Power Mode (G204).