Troubleshooting - Graco 115 VAC EGP Instruction Manual

Oil transfer pump
Hide thumbs Also See for 115 VAC EGP:
Table of Contents

Advertisement

Troubleshooting

Problem
Motor is running, but the pump
will not prime.
Oil is leaking in the motor
mount.
3A8568A
1. Follow Operation, page 7, before checking or
2. Check all possible problems and causes before
Cause
There is dirt under the pressure relief
valve.
The gears are worn or damaged.
The oil level is low.
There is an air leak in the suction
tube.
There is an air lock in the system.
The motor does not run at the proper
speed.
A faulty or damaged motor shaft seal. Replace the pump housing assembly.
The nozzle was closed for an
extended period of time during pump
operation.
A worn motor shaft.
repairing the equipment.
disassembling the equipment.
Remove the pressure relief valve and
inspect. Clean or replace the pump
housing assembly.
Remove the cover and inspect the
gears. If damaged, replace the pump
housing assembly.
Refill or replace the drum.
Inspect all joints in the suction tube
making sure that all threaded joints
have sealant applied properly. Fill
pump outlet port with oil.
Fill the system with fluid by keeping
nozzle open by operating the pump.
Check the electric connections.
Ensure the supply voltage is at the
proper level.
Do not exceed five (5) minutes of
operation with the nozzle closed.
Replace with a new pump.
Troubleshooting
Solution
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

25t82025t822

Table of Contents