To Order Order Replacement Replacement Parts Parts Order Replacement Parts information, as needed. 2. Please call Graco Customer Service to order. Please Please call Please call call your your distributor. your distributor. distributor.
Configuration Number Matrix Configuration Number Number Matrix Matrix Configuration Configuration Number Matrix Check the identification plate (ID) for the 20–digit Configuration Number of your pump. Use the following matrix to define the components of your pump. Sample Sample Sample Configuration Configuration Number: Configuration Number:...
Warnings Warnings Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
Page 6
Warnings WARNING WARNING WARNING EQUIPMENT EQUIPMENT EQUIPMENT MISUSE MISUSE HAZARD MISUSE HAZARD HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
Page 7
Warnings WARNING WARNING WARNING PLASTIC PLASTIC PLASTIC PARTS PARTS CLEANING PARTS CLEANING SOLVENT CLEANING SOLVENT SOLVENT HAZARD HAZARD HAZARD Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. • Use only compatible water-based solvents to clean plastic structural or pressure-containing parts.
Grounding Grounding Grounding Typical Floor Mount Installation, page 12, is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs. Tighten Fasteners Fasteners Before Before Setup Setup...
Installation Air and and fluid fluid hoses: fluid hoses: hoses: • Use only grounded hoses 2. Locate a bleed-type master air valve (B) close to with a maximum of 500 ft (150 m) combined hose the pump and use it to relieve trapped air. Be length to ensure grounding continuity.
Installation Air Exhaust Exhaust Ventilation Ventilation Exhaust Ventilation 2. Install a grounded air exhaust hose (U). Connect the muffler (T) to the other end of the hose. The minimum size for the air exhaust hose is 3/4 in. (19 mm) ID. If a hose longer than 15 ft (4.57 m) is required, use a larger diameter hose.
Installation Fluid Supply Supply Line Line Fluid Outlet Outlet Line Line Fluid Fluid Supply Line Fluid Fluid Outlet Line Typical Floor Mount Installation, page 12 Typical Floor Mount Installation, page 1. Use grounded flexible, fluid supply hoses (G). 1. Use grounded, flexible fluid hoses (L). See Grounding, page 8 Grounding, page 8 2.
Installation Typical Floor Floor Mount Mount Installation Installation Typical Typical Floor Mount Installation Figure 3 Typical floor mount installation A A A Air supply line J J J Fluid drain valve (required) B B B K K K Bleed-type master air valve (required for Fluid shutoff valve pump) C C C Air filter and regulator...
Operation Operation Operation Operation Pressure Relief Relief Procedure Procedure Pressure Pressure Relief Procedure 4. Open the fluid drain valve (installed on the system) to relieve all fluid pressure. Have a container ready to catch the drainage. Follow the Pressure Relief Procedure whenever you see this symbol.
Operation Start and and Adjust Adjust the the Pump Pump Start Start Adjust Pump 9. Slowly increase air pressure with the air regulator until the pump starts to cycle. Allow the pump to cycle slowly until all air is pushed out of the lines 1.
Maintenance Maintenance Maintenance Maintenance Maintenance Schedule Schedule Flushing and and Storage Storage Maintenance Maintenance Schedule Flushing Flushing Storage Establish a preventive maintenance schedule, based on the pump’s service history. Scheduled maintenance is especially important to prevent spills or leakage due to diaphragm failure. •...
Maintenance Torque Instructions Instructions Torque Torque Instructions NOTE: NOTE: NOTE: All fasteners for the fluid covers, center Fluid Fluid cover, Fluid cover, cover, center center diaphragm center diaphragm diaphragm joint, joint, joint, and and manifold manifold manifold diaphragm joint, and manifolds have a thread-locking fasteners: fasteners: 100 in-lb (11.3 N•m) fasteners:...
Dimensions and Mounting Dimensions and and Mounting Mounting Dimensions Dimensions Mounting Aluminum Aluminum Aluminum Aluminum and and SST Aluminum Aluminum A A A H H H 12.7 in (323 mm) 11.8 in (300 mm) 6.2 in (157 mm) B B B 14.4 in (366 mm) 12.9 in (328 mm) J J J...
Technical Data Technical Data Data Technical Technical Data Metric Metric Metric Maximum Maximum Maximum fluid fluid working fluid working working pressure pressure pressure 250 psi 1.72 MPa,17.2 bar Air pressure pressure pressure operating operating range operating range range 20-125 psi 0.14-0.86 MPa, 1.4-8.6 bar Fluid displacement displacement per...
California Proposition 65 Sound Sound Sound Power Power (measured per ISO-9614–2) Power At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm Low Pressure Setting 78 dBa High Pressure Setting 91 dBa At 100 psi (0.7 MPa, 7.0 bar) and full flow Low Pressure Setting 90 dBa High Pressure Setting...
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of five years from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.