Set Object Removal Detection - HIKVISION iDS-2CD7 G0 Series User Manual

Network bullet camera
Table of Contents

Advertisement

iDS-2CD7xxG0-xxxxx Network Bullet Camera User Manual
5. Optional: You can set the parameters of multiple areas by repeating the above steps.
6. For the arming schedule settings, refer to Set Arming Schedule. For the linkage method settings, refer
to Linkage Method Settings.
7. Click Save.

Set Object Removal Detection

Detects whether objects are removed from a pre-defined detection region such as exhibits on display. If it
occurs, the device can take linkage actions and the staff can take measures to reduce property loss.
Steps
1. Go to Configuration → Event → Smart Event → Object Removal Detection.
2. Check Enable.
3. Select a Region. For the region settings, see Draw Area.
4. Set the rule.
• Sensitivity (Range [1-100]): Percentage of body part of an acceptable target that leaves the pre-
defined region. Sensitivity = 100 – S1/ST*100 S1 is the target body part that leaves the pre-defined
region. ST is the complete target body.
EXAMPLE:
If you set the value as 60, a target will be counted as a removed object only when 40
percent body part of the target leaves the region.
• Threshold: Range [5–100s], the threshold for the time of the objects removed from the region. If you
set the value as 10, alarm is triggered after the object disappears from the region for 10s.
UM iDS-2CD7xxG0-xxxxx 021021NA
Figure 6-8 Set Rule
51