Device Installation Method 1: Installation on the wall ① 1.5m ② ① Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. Fix the back plate on the wall using wall mounting screws. ② Attach the device to the back plate. ③...
Standalone Installation Alarm Smoke detector Door Sensor Exit Button ZKBioSecurity Card TCP/IP Lock Reader Note: On this document, we just guide you to connect some normal components, if you want more connection of SRB, external fingerprint reader and so on, please check user manual document.
Lock Relay Connection The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally opened at power on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally closed at power on) is connected with 'NC' and 'COM' terminals. T NC Lock as an example below:...
Power Connection 12V DC Recommended power supply 1) 12V ± 10%, at least 00mA. 2) To share the power with other devices, use a power supply with higher current ratings. Quick Start User Registration View records User Authentication Verified User registration Register on the device Click >...
Page 8
Note: 1. It's recommended to register multiple administrators. 2. It's recommend enroll user's face in 0.5m distance, it's good for 1.4~1.8m height person. 0 5m Register on the software We recommend use ZKBioSecurity 3.1.5.0 or above. Please set the IP address and cloud service server address on the device. 1.
Page 9
2. Click [Personnel] > [Person] > [New] to register users in the software. 3. Add users to access levels. 4. Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices]. For more details, please refer to the ZKBiosecurity User Manual. Note: The icons in the standby interface indicates that the network connection or the server is abnormal.