3 TECHNICAL SPECIFICATIONS
Power supply voltage
Absorbed power
Motor max. load
Accessories max. current
(+24V)
BUS Accessories max.current
Operating ambient tempera-
ture
Fuses
Function logics
Work time (time-out)
Pause time
Terminal board inputs
Connector inputs
Terminal board outputs
Programmable functions
Learning functions
Integrated radio channels
type
3.1 DESCRIPTION OF COMPONENTS
J
POWER SUPPLY connector
J2
SERVICE LIGHT command terminal-board
J3
FLASHING LAMP terminal-board
J4
ELECTRIC LOCK terminal-board
J5
COMMANDS terminal-board
J7
MOTOR  terminal-board
J8
MOTOR 2 terminal-board
J9
Rapid connection for XF MODULE
J0
BUS terminal-board
J
BATTERY connector
SW
SET UP push-button
SW2
SPEED push-button
SW3
LOGIC push-button
DS
Programming Dip-switch
F
Accessories protective fuse
F2
Fuses protecting transformers and motors
LED
Signalling LEDs
230Vac (+6% -0%) - 50Hz
20W
50W x 2
00 mA
400 mA
-20°C - +55°C
F = self-resetting; F2 = T2A-
250V
EP , AP
 minute (fixed)
Varies according to learning
(max. 0 min.)
Open A, Open B, Stop, BUS
(I/O)
Power supply, battery
module XF 433 or XF 868
Motors, flashing lamp, power
supply to accessories,
electric lock, service light
contact (90 sec fixed)
Logic (AP , EP), Speed (high
3°/sec and low 0°/sec)
Pause time, leaf 2 delay at
closing
DS, SLH (max 250 channels)
LC (max 250 channels - FOR
SOME MARKETS ONLY)
3.2 DESCRIPTION OF TERMINAL-BOARDS
Terminal and/or
terminal-board

2
J5
3
4
5
J0
RED terminal
J2
GREY terminal
J3
ORANGE terminal
J4
BLUE terminal
J7
J8
Leaf 1 means the leaf which opens first during
the opening operation.
The service light control is active during the
entire gate opening or closing movement and
for the successive 90 seconds.
4 PROGRAMMING THE LOGIC
The function logic can be selected at any time by pressing
push-button SW3.
The selected logic is then displayed on LED LD7:
LED on
= AUTOMATIC STEPPED logic (AP)
LED off
= SEMIAUTOMATIC STEPPED logic (EP)
5 PROGRAMMING THE SPEED
The function logic can be adjusted at any time by pressing
push-button SW2.
The selected logic is then displayed on LED LD8:
LED on
= HIGH speed (3 °/sec)
LED off
= LOW speed (0 °/sec)
3
Description
Device connected
Power supply for
+24V
accessories
GND
Negative
Device with NC
contact which causes
STOP
the automated
system to shut down
OPEN B
Device with N.O
contact (see chap.
FUNCTION LOGICS)
OPEN A
Safety devices with
BUS
BUS technology
Service Light control
SERVICE
output (connect a
LIGHT
relay coil at 24Vdc-
00mA max)
Flashing lamp 24Vdc
LAMP
- 5W
Electric lock 2Vac or
LOCK
24 Vdc (to be installed
on leaf )
MOT
Motor  (leaf )
MOT2
Motor 2 (leaf 2)

Advertisement

Table of Contents
loading

Table of Contents