STA-RITE SG12 Series Installation, Operation & Parts Manual page 6

Grinder pumps
Table of Contents

Advertisement

Available languages

Available languages

Connect thermostat (black and white leads in control cable)
in series with magnetic starter operating coil so that in case
of overheating, pump will shut down. Failure to connect ther-
mostat circuit voids warranty.
Connect red lead of leak detection circuit to leak detection
probe. Green lead is connected to pump case; connect it to
ground or neutral side of indicating circuit. Either connect
seal leak detection circuit (red and green wires in control
cable) to an indicating circuit in control panel (to show seal
failure) or monitor circuit with an ohmmeter periodically. A
drastic drop in resistance across detection circuit indicates
seal failure.
Locking
Bracket
Angle Bracket
Upper
Rail Bracket
Guide Rail
Stationary
Flange
Base
Flange
Figure 5: Lift-out Guide System Nomenclature; illustra-
tion shows setup for SGC20.
Single phase units
that are not installed
with Sta-Rite control
panels require a
capacitor/overload
package. Purchase
the package through
the Sta-Rite catalog.
Locking Rail
Movable Flange
(Short Nipple
Under Flange)
Eyebolt
Discharge
Pipe Bracket
Ball Check Valve
Long Nipple
Guide Rail
Bracket
Union
Short Nipple
1940 0895
Power
Cable
230 VOLTS
L1
Black
L1
L2
White
L2
Red
L3
L3
P1
Ground
P2
Control
S
Cable
(16-4)
Black
P1
White
P2
Red
S
Green
Ground
Figure 6: SGC Three Phase Sensor Circuit Electrical Connections; see Table I, Page 2 to
determine if your pump has thermal or leak sensors.
MOTORS
Single Phase: NEMA design L or M with class B insulation.
Suitable for operation in liquids with a maximum temperature
of 40°C (104°F).
L
1
START
CAPACITOR
2 1
5
START
RELAY
RUN CAPACITOR
CONTROL BOX
Figure 7: SG12/SGC12 and SG13/SGC13 Single Phase
Electrical Connections without sensors.
L1
L2
Start
Capacitor
Start
Relay
2 1
5
Run
Capacitor
CONTROL BOX
Figure 8: SGC12/SGC13 and SGC20 Single Phase
Electrical Connections with sensors.
460 VOLTS
1
1
T1
&
T1
T7
L1
2
2
&
T8
L2
T2
T2
3
3
&
T3
T9
T3
L3
4
4
P1
P1
P1
5
5
P2
P2
P2
6
6
S
S
S
7
7
T4,T5,T6
T4 & T7
8
8
T5 & T8
Not Used
9
9
Not Used
T6 & T9
Terminal Board
6
L
2
POWER
CABLE
(14-4)
GREEN
BLACK
(COM)
WHITE
(MAIN)
RED
(START)
Power
Cable
(14-4)
Ground
(Green)
Black
(Common)
White
(Main)
Red
(Start)
Black
White
Red
Ground
(Green)
T1
T4
T8
T7
T7
T9
T6
T9
T6
T3
T3
T5
T6
P1
Thermal Sensor
P2
S
Leak Sensor Probe
T
1
T
4
T
5
T
8
PUMP
1943 0895
T1
Main
Winding
T4
T5
Start
Winding
T8
PUMP
P1
P2
Thermal
Sensor
Leak Sensor Probe
T1
T4
T8
T5
T2
N
C
N
O