STA-RITE SG11200 Series Owner's Manual

STA-RITE SG11200 Series Owner's Manual

Submersible grinder pump

Advertisement

Quick Links

293 Wright Street, Delavan, WI 53115
© 2007 PRINTED IN U.S.A.
SG11200 Series
Installation/Operation/Parts
For further operating, installation,
or maintenance assistance:
Call 1-262-728-9181
OWNER'S MANUAL
Submersible Grinder Pump
S684 (Rev. 8/14/07)

Advertisement

Table of Contents
loading

Summary of Contents for STA-RITE SG11200 Series

  • Page 1 OWNER’S MANUAL Submersible Grinder Pump 293 Wright Street, Delavan, WI 53115 SG11200 Series Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-262-728-9181 S684 (Rev. 8/14/07) © 2007 PRINTED IN U.S.A.
  • Page 2: Unpacking And Inspection

    Safety UNPACKING AND INSPECTION 4. Do not install the pump in any location classified as hazardous by National Electrical Code, ANSI/NFPA Handle with care. Check the items received against the 70-1984. packing list to be sure that all equipment has been 5.
  • Page 3: Installation / Electrical

    Installation / Electrical INSTALLATION 1. DO NOT splice the power cord. 2. DO NOT handle or service the pump while it is con- This pump may be installed on a guide-rail lift-out sys- nected to the power supply. tem for ease of inspection and service. Guide rails allow removal of the pump without disturbing the piping or 3.
  • Page 4 A full range of con- Black trols and switches is listed in our catalog. If a Sta-Rite control panel is not used, install a control panel with circuit breaker or fused disconnect as required by local code. Use magnetic starters with ambi- ent compensated overload protection.
  • Page 5: Operation

    Operation / Maintenance OPERATION MAINTENANCE Hazardous cutter and possible Only qualified mechanics with proper tools and knowl- unexpected starts. Rotation of the edge should attempt to service this pump. cutter with hands in the cutter NOTICE: Whenever bearing bracket is being removed area can cause loss of fingers.
  • Page 6 Maintenance NOTE: BE SURE you have the correct capscrews – the Installing the New Shaft Seal wrong ones will release the seal plate from the bracket NOTE: Install all new O-Rings, seals, and gaskets during and also release a lot of oil! reassembly.
  • Page 7: Troubleshooting

    Troubleshooting Hazardous voltage. Can shock, burn, or Hazardous cutters and unexpected starts kill. Disconnect power before attempting any service or which can cause loss of fingers. Keep hands away from repair work on pump. pump suction inlet when working on or servicing pump. SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION...
  • Page 8: Repair Parts

    Repair Parts Seal Plate Bearing Bracket Volute Seal Retaining Ring 4333 0203 Part Description Qty. SG11200220M SG11200320M Cord E01-1241-5 E01-1241-5 Capscrew M6x25 Capscrew Run Capacitor (12 mfd, 450V) E14-0121-0 – Start Capacitor (150 mfd, 250V) E14-1503-0 – Capscrew – Capscrew –...
  • Page 9: Limited Warranty

    LIMITED WARRANTY Sta-Rite Industries warrants to the original consumer of the products listed below, that they will be free from defects in material and work- manship for the Warranty Period from the date of original installation or manufacture as noted.