10.2 General preconisation maintenance

Before each reassembly
ATTENTION
Before any intervention, it is imperative to follow the
decompression procedure and the safety instructions.
 Clean the parts with the appropriate cleaning solvent.
 Fit new seals if necessary, after greasing them.
 Grease the piston and the inside of the cylinder to avoid
damaging the seals.
 Fit new parts if necessary.