Note!
6.3

Cabling

Note!
6.4

Grounding the units

6.5

DIP switch and jumper settings

Note!
51
The foam rubber should be kept for re-use if the Master compass has to be
sent to factory for service!
No cables are included when the Gyro system is delivered from factory.
The wiring diagrams on page 84 onwards include cable specifications for
all cables.
Connect power and signal cables according to the wiring diagrams on
page 84 onwards.
To avoid cables to loosen due to vibration; the cables could be fastened to
the fixing device using wire straps as illustrated in the figure.
All units in the GC80/85 system should have a proper ground connection
from the unit's ground terminal.
The wires should be as short as possible and have a cross section of at least
AWG13 (2.5mm
).
2
MASTER COMPASS
GC80 and GC85 Gyro systems include several DIP switches and jumpers.
With the exception of 2 switches on the ICNT board in the Control unit, no
switches have to be set when installing the system. These 2 switches are
set to configure the Control unit to match the type of Gyro system (GC80
or GC85), and to activate an external heading sensor.
All DIP switch settings are read when the system is started. Any changes
made while the system is running will therefore not take effect until the
system is restarted.
For a complete list of DIP switch settings, refer to
page 101.
Simrad GC80/85 Compact MK2 Gyro Compass
COMPACT MK2
CONTROL UNIT
DIP SWITCH SETTINGS
POWER SUPPLY
UNIT (OPTION)
,
988-12718-003