Acknowledging An Alarm; Fault Finding; Main Power Failure - Simrad GC80 Compact MK2 User Manual

Gyro compasses
Hide thumbs Also See for GC80 Compact MK2:
Table of Contents

Advertisement

13.2

Acknowledging an alarm

ACK
ENT
13.3

Fault finding

Caution
111
An alarm is acknowledged by pressing the ACK/ENT button.
-
The audible alarm will be silenced.
-
If the alarm situation has disappeared, the alarm lamp will be
switched off, and the alarm code will be removed from the LCD.
-
If the alarm situation continues, the alarm lamp will switch from
flashing to steady light. The LCD will return to show true bearing
with flashing numbers to indicate that the bearing may have large
errors.
An alarm code for an active error may be recalled by pressing the DISP
button until the alarm display is shown. It is possible to recall any alarm
code in the LCD for as long as the alarm situation is present.
When an alarm is generated and not removed by pressing the ACK/ENT
button, further actions should be taken to correct the alarm situation.
The following pages present an overview of symptoms and corrective
actions for errors that may be corrected by the operator. If none of these
procedures correct the problem, contact the local Simrad dealer for advice
or to request on-board service.
Before any fault-finding procedure is started, the following actions should
be performed to verify a system error:
1
Shut down and restart the Gyro compass.
2
Verify that all cables are properly connected according to the
wiring diagrams, page 84 onwards.
3
Check the cables from the main power supply to the Control unit.

Main power failure

Alarm generated when the main power supply is lost.
Turn OFF the power as described on page 20 before checking the main
power supply.
1
Verify that the main power switch inside the Control unit is
switched ON.
ALARM MESSAGES AND CORRECTIVE ACTIONS