Summary of Contents for Wren Kitchens TOWER UNIT 2070 x 600 50/50
Page 1
TOWER UNIT Boiler Housing Assembly Guide 2070 x 600 2070 x 600 50/50 70/30 2250 x 600 Tall 2250 x 600 Tall 50/50 70/30 For Internal Use: FI.WR.INS.059_WKIN00180_TOWER_600_2DrBoilerHousing_Rev2.indd...
TOWER UNIT BEFORE YOU START Boiler Housing INSTALLATION SHOULD BE Assembly Guide PERFORMED BY A COMPETENT PERSON ONLY. THIS PRODUCT COULD BE DANGEROUS IF INCORRECTLY INSTALLED Panel B Panel C Btm Panel C Top Panel E Legs Frontal (packed separately) x2 End Panel x2 Base Panel x2 Rail...
Page 3
TOWER UNIT Step 1. Seat cam dowel (G) into holes in both end panels (B) Boiler Housing as shown. Seat (G) Assembly Guide cam dowel into hole as Step 2. shown. Seat dowel (F) into holes in both end panels (B) as shown.
Page 4
TOWER UNIT Boiler Housing Assembly Guide Front Step 5. Secure each of the legs into place with C Btm 2 x 15mm screws (L) per leg Ensure legs are rotated as shown so that part of it is supporting the end panels (B). Front legs should have flat edge to the front.
Page 5
TOWER UNIT Step 8. Attach hinge plates onto end panels (B) In Boiler Housing locations shown using 8 x 15mm screws (L) 2070 Hinge side to be mounted in accordance Assembly Guide to customer kitchen plan. 70/30 50/50 HINGE HINGE POSITION POSITION 1826mm...
Page 6
TOWER UNIT Step 9. Boiler Housing Attach hinge plates onto end panels (B) In locations shown using 8 x 15mm screws (L). 2250 Assembly Guide Hinge side to be mounted in accordance to customer kitchen plan. N.B. For appliance shelf, secure to panel (B) using 4 x brackets (FF) locate according to customer appliance requirements.
Page 7
TOWER UNIT Boiler Housing Assembly Guide Screw into any side units using the 30mm screws (K) provided to secure to unit. Screw just to the rear of the Hinge Mounting Plate, at the top and bottom of both sides of the unit, place a cover cap on the head to conceal it.
Page 8
TOWER UNIT See Customer Specific Kitchen Plan For Tower Frontals Boiler Housing Assembly Guide Step 10. Insert hinge where required in holes as shown. Step 11. Secure hinges by tightening 2 x screws with hinge dowels attached. These are already positioned within the hinges.
Page 9
TOWER UNIT Boiler Housing Assembly Guide For Internal Use: FI.WR.INS.059_WKIN00180_TOWER_600_2DrBoilerHousing_Rev2.indd Page 8...
Page 10
TOWER UNIT Boiler Housing Assembly Guide Page 9 For Internal Use: FI.WR.INS.059_WKIN00180_TOWER_600_2DrBoilerHousing_Rev2.indd...
Page 11
TOWER UNIT Boiler Housing Assembly Guide For Internal Use: FI.WR.INS.059_WKIN00180_TOWER_600_2DrBoilerHousing_Rev2.indd Page 10...