Electrical / Refrigeration - Hussmann microSC VRL1B Installation & Operation Manual

Low temperature self contained glass door merchandisers with r-290 refrigerant
Table of Contents

Advertisement

P/N 3034040_H
PLUG
The plug cord is 9ft long and is located on
the right hand rear of the merchandiser.
Disconnect power before servicing. VRL
merchandisers require a dedicated electrical
circuit with ground. 12AWG is the minimum
sized acceptable wire.
Merchandiser must be grounded.
Do not remove the power supply cord ground.
• The VRL1B requires a dedicated
15 AMP/208-230V circuit with a grounded
wall receptacle (NEMA L6-15P).
• The VRL2B requires a dedicated
15 AMP/208-230V circuit with a grounded
wall receptacle (NEMA L6-15P).
• The VRL3B requires a dedicated
20 AMP/208-230V circuit with a grounded
wall receptacle (NEMA L6-20P).
• Always use a dedicated circuit with the
amperage stated on the unit.
• Plug into an outlet designed for the plug.
• Do not overload the circuit.
• Do not use long or thin extension cords.
Never use adapters.
• If in doubt, call an electrician.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

ELECTRICAL / REFRIGERATION

ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES
NEMA L6-15P
VRL1B
VRL2B
Risk of Electric Shock. If cord or plug
becomes damaged, replace only with
a cord and plug of the same type.
Nominal
Minimum
Voltage
Voltage
208-230
— LOCK OUT / TAG OUT —
To avoid serious injury or death from electrical
shock, always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.
NEMA L6-20P
VRL3B
Maximum
Voltage
188
253
VRL Merchandisers
13