Defrost Heater Replacement - Hussmann microSC VRL1B Installation & Operation Manual

Low temperature self contained glass door merchandisers with r-290 refrigerant
Table of Contents

Advertisement

P/N 3034040_H

DEFROST HEATER REPLACEMENT

There are 2 heaters installed in the evaporator
compartment. Evaporator heater and drip pan
heater. The function of the evaporator heater
is to melt the ice built in the fins.
The defrost heaters are firmly embedded in
the evaporator and held in place with spring
clips. To remove the heater: first remove all
spring clips and pull the defective heater out
of the slots in the evaporator, starting at the
wire supply lead.
The replacement heater should be firmly seated
in the slots by using a small block of wood
and a mallet. After the new heater is in place,
replace all the spring retaining clips to assure
heater retention. One lead of the defective
heater may be used to pull the new leads
through the cabinet to the respective terminals
as marked on each lead.
NOTE: Care must be taken to ensure the drain
stub is correctly inserted in the cabinet drain
tube for proper drainage.
1. Remove screws from drip pan. The screws
are located 2 of each side, the rest in the
door side (front).
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Door Side
Drain Side
The picture shows a 3 door case as reference.
The amount of yellow screws may vary
acordingly.
2. Tilt the drip pan to access the coil heaters.
3. Identify the defrost heater leads, and
unscrew them from terminal block by using
a screw driver.
35
VRL Merchandisers

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microsc vrl2bMicrosc vrl3b

Table of Contents